Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
GRILL THERMOSTAT
Refer to page 4-24 for the procedure for ac-
cessing the grill thermostat.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the
thermostat terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
thermostat terminals. The meter should
indicate a closed (0 Ω) circuit.
Electrical Shock Hazard
GRILL ELEMENTS
Refer to page 4-24 for the procedure for ac-
cessing the grill elements.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect one of the wires from the grill
element terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
element terminals. The meter should in-
dicate as follows:
Halogen Grill Element = 2 ±1 Ω
Softstart Quartz Element = 6 ±2 Ω
Quartz Grill Heater = 29 ±5 Ω