CALIBRATING THE DISPENSER

NOTE: The SLCC-6 is calibrated at the factory and does not normally need to be re-calibrated. To enter the
Calibration Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position and then hold the MENU
switch down for 10 seconds.
LCD DISPLAY
C
1
r u n
MENU
(-)
C
1
4 3
MENU
(-)
C
2
r u n
MENU
(-)
C
2
4 3
MENU
(-)
C
3
r u n
MENU
(-)
C
3
4 1
MENU
(-)
CALIBRATION MODE
Left (Decaf) Pump Cal.
(+)
Left (Decaf) Pump Cal.
(+)
Right (Regular) Pump Cal.
(+)
Right (Regular) Pump Cal.
(+)
Left (Decaf) Water Rate
(+)
Left (Decaf) Water Rate
(+)
DESCRIPTION
Set PRIME-NORMAL-RINSE switch
to PRIME position.
Press the DECAF button, left pump
will run for 20 seconds. Refer to Field
Calibration of the Concentrate Pumps
Enter ml collected from the 20 sec.
test above.
Default = 43
Set PRIME-NORMAL-RINSE switch
to PRIME position
Press the COFFEE button, right pump
will run for 20 seconds. Refer to Field
Calibration of the Concentrate Pumps
Enter ml collected from the 20 sec.
test above.
Default = 43
Set PRIME-NORMAL-RINSE switch
to RINSE position
Press the DECAF button, water will
flow for 20 seconds. Refer to Field
Calibration of the Concentrate Pumps
Enter Liters collected from 20 sec.
test above
Default = 41