SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. #00656.0000 #00831.0000 #00658.0000 CAUTION WARMERS AND SURFACES ARE HOT POUR IN WATER ONLY #02763.0000 #12364.0000...
" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.
Page 5
PLUMBING REQUIREMENTS (cont.) MODELS W/OUT FAUCET Models CT, CWT, CTF, CWTF, SINGLE CW & SINGLE CWF Flush the water line and securely attach it to the flare fitting on the strainer or tee. Turn on the water supply. On CTF, CWTF and SINGLE CWF Models, place an empty vessel beneath the faucet and lift the handle until water is dispensed.
4B. Models CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF Connect the brewer to the power source, place the "ON/OFF" switch in the "ON" upper position, and momentarily press and release the start switch.
Pour one pitcher of tap water into the screened area on top of the brewer. 5B. Models CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF Place the "ON/OFF" switch in the "ON" upper position. Momentarily press and release the start switch.
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
Page 9
TROUBLESHOOTING (cont.) PROBLEM Brew cycle will not start (cont.) (CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF) Water is not hot PROBABLE CAUSE 3. ON/OFF Switch 4. Start Switch 5. Timer 6. Solenoid Valve 7. Water strainer/flow control (.222 GPM)
Page 10
TROUBLESHOOTING (cont.) PROBLEM Inconsistent beverage level in dispenser Consistently low beverage level in the dispenser (CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF) Spitting or excessive steaming PROBABLE CAUSE 1. Strainer/flow control (.222 GPM) (CT,CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW &...
Page 11
3. Solenoid Valve (CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF) 1. Timer (CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF) 1. Solenoid Valve (CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW &...
Page 12
TROUBLESHOOTING (cont.) PROBLEM Weak beverage Dry coffee grounds remain in the funnel Brewer is making unusal noises (CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF) PROBABLE CAUSE 1. Filter Type 2. Coffee Grind 3. Sprayhead 4.
Page 13
TROUBLESHOOTING (cont.) PROBLEM Brewer is making unusal noises (cont.)(CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF) Brewer is making unusal noises Low beverage serving tempera- ture Brewer does not change volume when half/full switch is changed.
SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service personnel.
SERVICE (cont.) CONTROL THERMOSTAT MODEL C MODEL CWT MODEL SINGLE CW Location: The control thermostat is located inside the trunk on the left side of the component bracket. Test Procedures: Disconnect the brewer from the power source. Locate the blue wire on the control thermostat. Check the voltage across the blue wire on the control thermostat and the white insert on two pole 120 volt terminal block or three pole 120/...
SERVICE (cont.) CONTROL THERMOSTAT (cont.) Slide the grommet to the line 4.5" above the bulb on the new capillary tube. Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid.
SERVICE (cont.) ON/OFF SWITCH - MODEL C D IS D IS IF : IF : D IS D IS IF : IF : D IS D IS IF : IF : D IS D IS IF : IF : ON/OFF SWITCH - MODEL CWT & SINGLE CW ®...
Page 18
SERVICE (cont.) ON/OFF SWITCH (cont.) Test Procedure: Disconnect the brewer from the power source. Viewing the switch from the back remove the white or red wire from the upper terminal and the black wire from the center terminal. Check the voltage across the white wire or red wire and the black wire with a voltmeter.
SERVICE (cont.) SOLENOID VALVE - CT, CWT & SINGLE CW Location: The solenoid valve is located inside the trunk on the lower center part of the component bracket. Test Procedures: Disconnect the brewer from the power source. Disconnect the white/blue and white/green wires from the solenoid valve.
Refer to the following illustration when recon- necting the wires. PNK from timer TAN from timer START SWITCH - CT, CWT & SINGLE CW Location: P1153 The start switch is located in the center front of the hood.
SERVICE (cont.) TANK HEATER Location: The tank heater is located inside the tank and secured to the tank lid. Test Procedures: Disconnect the brewer from the power supply. Check the voltage across the black and white wires on 120 volt models or the black and red wires for 120/240 volt models, 200 volt models and 230 volt models with a voltmeter.
SERVICE (cont.) TANK HEATER (Cont.) 15. Reconnect the wires to the limit thermostat, tank heater and control thermostat. See limit thermo- stat and control thermostat sections in this manual when reconnecting wires. 16. Install fill basin, secure with tank inlet fitting and gasket.
Page 23
Gently pull the thermostat sensor and grommet from the tank lid. Insert a tube to the bottom of the tank and syphon ALL of the water out. (BUNN-O-MATIC has #12440 syphon assembly available for this pur- pose. Gently reinstall the thermostat sensor and grom- met in the tank lid.
SERVICE (cont.) DIAL TIMER (Early Models) - CT & CWT Dial Timer Location: The timer is located inside the front of the trunk on the upper right side of component bracket. Test Procedure (Dial Timer). Disconnect the brewer from the power source.
Page 25
SERVICE (cont.) DIAL TIMER (Early Models) (cont.) To Main Wiring Harness WHI to Solenoid Valve BLK to Solenoid Valve Dial Timer DIGITAL BREW TIMER (Late Models) DIGITAL BREW TIMER Location: The timer is located inside the front of the trunk on the upper right side of component bracket.
Page 26
SERVICE (cont.) DIGITAL BREW TIMER (Late Models)(cont.) 4. Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 21 when reconnecting the wires. 5. Install new circuit board with spacers (as re- quired) to the component mounting bracket.
SERVICE (cont.) WARMER ELEMENT(S) Location: The warmer element(s) is located under the warmer plate. Test Procedures: 1. Disconnect the brewer from the power source. 2. Use the white or red wire to the terminal block and the white/red, brown/black or violet wire to the "ON/OFF"...