Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.
Troubleshooting Instructions
If a fault occurs, count the number of red flashes between pauses and refer to the table below:
Red Flashes
Specifications
DC Output – see Operating Instructions
QuiQ Model:
Voltage-nom (V)
Voltage-max (V)
Current-max (A)
Battery Type
Reverse Polarity
Short Circuit
AC Input
All models
Voltage-max (Vrms)
Frequency (Hz)
Current - max (Arms)
Current – nom (Arms)
AC Power Factor
Mechanical
All models
Dimensions
Weight
Environmental
Operating
Temperature
Storage Temperature
AC input connector
DC output connector
Product warranty is dependent on model - please contact dealer of original equipment for warranty service.
Note: This is a Class A product. In a domestic environment this product may cause radio interference, and the user may be required to take adequate measures.
2012 © Delta-Q Technologies Corp. All rights reserved. PN: 710-0099 Rev 3
Cause
Charge Enable Fault or
Battery Temperature Fault
Battery Voltage Too Low or High
Charge Timeout caused by battery
pack not reaching required voltage.
Charger output was reduced due to
high temperatures.
Check Battery: battery could not be
trickle charged up to minimum voltage
Over-Temperature: Charger shut
down due to high internal
temperature.
Charger Internal Fault
913-4810-01
913-4810-E5
913-4810-02
913-4810-EZ
913-4810-E3
922-4852-E6
48
67.2
16
13
Flooded Lead-Acid
Electronic protection – auto-reset
Electronic current limit
85 – 265
45 - 65
10A @ 104VAC
(reduced by 10% < 104VAC)
9A @ 120VAC / 4.5A @ 230VAC
>0.98 at nominal input current
28.0 x 24.5 x 11.0 cm (11 x 9.7 x
4.3")
<5 kg (11 lbs)
Enclosure: IP46
-30°C to +50°C (-22°F to 122°F),
derated above 30°C, below 0°C
-40°C to +70°C (-40°F to 158°F)
IEC320/C14
(require •1.8m localized cord)
OEM specific w/ 14AWG wire
APPENDIX A
Solution
Check connector contacts and retry.
Check that battery temperature is between
-10°C and +50°C.
Check that battery voltage is between
12.0V and 55.2V and retry.
Check voltage during charge is < 67.2V.
Check for loose connections or corrosion.
Operate charger at a lower ambient
temperature or increase cooling air flow.
Check for shorted or damaged cells.
Ensure sufficient cooling air flow and reset
charger (interrupt AC power for 15
seconds).
Reset charger (interrupt AC power for 15
seconds). Return to qualified service depot
if fault persists.
Operation
All models
Battery Temperature
Compensation
Maintenance Mode
Auto-restart if V < 2.08V/cell
Regulatory
Safety
EN 60335-1/2-29
Safety of Appliances/ Battery Chargers
st
UL2202 (1
Ed.)
EV Charging System Equipment
UL1564 2nd Ed.
Industrial Battery Charger
CSA-C22.2 No.
Battery Chargers- Industrial
107.2
Emissions
FCC Part 15/ICES
Unintentional Radiators Class A
003
EN 55011
Radio disturbance characteristics
EN 61000-3-2
Limits for harmonic current emissions
EN 61000-3-3
Limits of voltage fluctuations and
Immunity
EN 61000-4-2
Electrostatic discharge immunity
EN 61000-4-3
Radiated, radio-frequency,
EN 61000-4-4
Electrical fast transient/burst immunity
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
Voltage variations immunity
Automatic
or 30 days elapse
(Class A)
flicker
EMF immunity
Surge immunity
Conducted Immunity
A - 3