Mitsubishi Heavy Industries FDC280KXZE1 Service Manual page 61

Kxz standard and corrosion protection treatment series vrf inverter multi-system air-conditioners
Table of Contents

Advertisement

Code
Write-in contents
No.
66
Compressor 2 cumulative operating time (estimate)
67
Compressor 1 start times
68
Compressor 2 start times
Control status
69
CM1 3-minute delay timer
Control status
70
CM2 3-minute delay timer
Control status
71
CH compressor protection timer
Control status
72
CH compressor protective start
Control status
73
Oil equalization
Control status
74
Oil return
Control status
75
Defrost kinds + defrost status
76
Control status
Low pressure error (cooling) return status
77
Control status 1
78
Control status 2
Data write-in
Number of
Write-in unit
range
bytes
0~65535
h
2
0~65535
20 times
2
0~65535
20 times
2
1 second
0~180
1
0~180
1 second
1
0~360
3 minutes
1
0~15
1
0~127
1
0~2
1
0~127
1
0~4
1
1
1
59
-
29
-
-
-
'14 • KX-SM-202
Record data
Contents
15
Protective start end
0~14
During protective start
0
None
1
Oil equalized rotation
10
Oil equalized operation 1
20
Oil equalized operation 2
30
Oil equalized operation 3
41
Oil equalized operation 4-1
42
Oil equalized operation 4-2
51
Oil equalized operation 5-1
52
Oil equalized operation 5-2
61
Oil equalized operation 6-1
62
Oil equalized operation 6-2
71
Oil equalized operation 7-1
72
Oil equalized operation 7-2
81
Oil equalized operation 8-1
82
Oil equalized operation 8-2
0
None
1
Oil return (cooling)
2
Oil return (gas cycle)
0
None
11
Thermal condition defrost status 1
12
Thermal condition defrost status 2
13
Thermal condition defrost status 3
14
Thermal condition defrost status 4
21
Strength type thermal condition defrost status 1
22
Strength type thermal condition defrost status 2
23
Strength type thermal condition defrost status 3
24
Strength type thermal condition defrost status 4
31
Time condition defrost status 1
32
Time condition defrost status 2
33
Time condition defrost status 3
34
Time condition defrost status 4
Normal operation
0
Compressor OFF
1
For 70 seconds after compressor ON
2
After 70 to 180 seconds after compressor ON
3
After 180 to 195 seconds after compressor ON
4
Bit0
Super Link communication state
Bit1
In trial operation control
Bit2
In demand control
Bit3
Silent mode
Bit4
Spare
Bit5
Spare
Bit6
Spare
In pump-down control at
Bit7
Start/Stop
In low outdoor temperature
Bit0
control
In for replacement pump-down
Bit1
control
Bit2
Compressor dilution protection
Outdoor heat exchanger
Bit3
refrigerant purge
Indoor heat exchanger
Bit4
refrigerant purge
Bit5
Spare
0: SL (old SL)
1: SL (new SL)
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice
0: Normal
1: Practice