Superabrasive
9.8 CHECKING THE TENSION OF THE BELT
Figure 9.8.1
Open the checking cover to reach the belt and tension device (Fig.9.8.1). While tensioning check regularly tension. It is
recommended that the tensioning of the belt be measured with Optikrik II Device (Measuring range: 500 ‐1400 N) (Fig.9.8.2).
Fastening force is 520 N.
ATTENTION:
NEVER "OVER" TENSION THE BELT, THE BELT WILL BE DESTROYED AND IT WILL NEVER RECOVER ITS ORIGINAL TENSION Loose the
contra nuts (Fig.9.8.3), loose light the two nuts of the tension device (Fig.9.8.4), and adjust the tension with the nut seen in. When
the right tension is reached: close the contra nuts and the two nuts of the support. Reassemble in the same manner.
PLEASE MAKE SURE YOU CHECK THE TENSION OF THE BELT AFTER THE FIRST 15 HOURS OF OPERATION
9.9 MOTOR CONNECTION
In case of changing the motor, please check the cable connection to your motor.
Lavina®20 S
The motor is connected in "Delta" (Triangle) 230 Volt, reminder for the wire connection of the motor.
User Manual
Figure 9.8.2
Original Language
Figure 9.8.3
26
Lavina® 20‐S
Figure 9.8.4
Figure 9.9.1