Roland VersaCamm SP-540i User Manual page 101

Hide thumbs Also See for VersaCamm SP-540i:
Table of Contents

Advertisement

2.
Execute the [ADJUST BI-DIR] menu item.
Load the media.
P. 32, "Loading Media," p. 82, "How to Load Sheet Media"
Perform bidirectional adjustment.
P. 73, "Correcting for Misalignment in Bidirectional Printing," p. 74, "Correcting for Misalignment in Bidirectional Printing More
Precisely"
3.
Print a test pattern and cut it.
MENU
CUTTING MENU
CUTTING MENU
CROP - CUT ADJ.
CROP - CUT ADJ.
TEST PRINT
Cutting position and printing
position are misaligned.
When adjustment is needed, go on to the steps below.
4.
Print and cut a test pattern for adjustment.
CROP - CUT ADJ.
TEST PRINT 2
5.
From the test pattern, read the correction value at the location.
Test pattern
Correction-value scale
Check the value on
the [FEED] side.
4-9 Performing Printing and Cutting Separately
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Cutting
position
Printing
position
Cutting position and printing
position are aligned.
Press
.
Press
to execute.
Check the value on
the [SCAN] side.
Scan direction
Cutting line
Cutting
position
Printing
position
Cutting line
The point where the cutting line
intersects the correction-value scale is
the correction value. In this figure, the
value is "-0.3." Use the same method
to read the value on the [FEED] side.
99