Voltage Selector Switch - Honda EG4000CL Owner's Manual

Hide thumbs Also See for EG4000CL:
Table of Contents

Advertisement

Voltage Selector Switch

The power available to each receptacle depends on the position of the
voltage selector switch.
Switch
Receptacle
Position
120V ONLY
120V/240V
120V ONLY Position
When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles. You must, however,
make sure the load on any receptacle does not exceed its available
power shown below and the total load does not exceed the total
current available.
Total Current Available:
30.0 A (EG4000CL)
37.5 A (EG5000CL)
45.8 A (EG6500CL)
EG4000CL
30A at 120V
20A at 120V
20A at 120V
20A at 120V
None
15.0A at 120V
15.0A at 120V
15.0A at 120V
15.0A at 240V
-
OPERATION
Available Power
EG5000CL
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
18.8A at 120V
18.8A at 120V
18.8A at 120V
18.8A at 240V
EG6500CL
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
22.9A at 120V
20A at 120V
20A at 120V
22.9A at 240V