Honda EG5000X Owner's Manual

Honda EG5000X Owner's Manual

Honda portable generator owner's manual
Hide thumbs Also See for EG5000X:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Honda EG5000X

  • Page 2 generator not expose the generator wet, and do not operate is a potential source of electrical to moisture, rain or snow. it with hands. shock if misused. Do not let the generator...
  • Page 3 Honda generator. and maintenance of the EG5000X is based on the latest product may be reproduced without a permanent part of the generator preceded by the following personal injury or death will result if...
  • Page 4: Table Of Contents

    CONTENTS GENERATOR SAFETY..COMPONENT IDENTIFICATION.. PRE-OPERATION STARTING THE ENGINE..GENERATOR USE..STOPPING THE ENGINE..High altitude operation.. MAINTENANCE.. TRANSPORTING/STORAGE TROUBLESHOOTING 10. WIRING DIAGRAM 11. SPECIFICATIONS 12. WARRANTY SERVICE..CHECK..‘..: ...
  • Page 5 Place the generator on a firm, generator is tilted or overturned, overturned or sinks into generator. e To prevent fire hazards least 4 meter (3 feet) away Do not place flammable @ Know to stop the generator controls, Never permit @ The generator is a potential the generator...
  • Page 6 Read these labels before you operate the generator. ELECTROC”T,ON OR PROPERTY DAMAGE CAN OCCUR. W NOT CONNECT THlS GENERATOR BUILDINO’S ELECTR,CAL SYSTEM UNLESS LSOLATlON WITCH HAS BEEN INSTALLED 11 FUEL GASOLINE (PETROL)
  • Page 7 HClifCK FOR SPILLED FUEL OR FUEL LtAKS. STOP ENGINE BtfORE RWELIN~. ~CONTROLfR OU’IL NY A MI FUIIE HI tSSENCt REPANOUE SUR L’APPAREIL ARRETER Lf MOIEUR AVANT Of RfFAIRf ~INSPECCIONAR PARA COMBUSIIRLE OfRRAMAOO 0 ESCAPE. PARAR MGTllR ANTlS OF 03lAR IT USE INDOORS. EXHAUST GAS CONTAINS IEPASUTILISERDANSUNENDRDITFERMEACAUSE U RISDUED'EMPDISDNNEMENT EN 'LUGARES CERRADDS PDRDUE EL...
  • Page 8 CHOKE LEVER CARBURETOR DRAIN SCREW SEDIhENT RECOIL OIL ALERT VOLTAGE LAMP SWITCH ENGINE SWITCH STARTER GRIP SELECTOR ‘ACLER ENGINE OIL FILLER EN&NE OIL DRAIN PLUG...
  • Page 9 FUEL FILLER MUFFLER GROUND TERMINAL...
  • Page 10: Check

    CAUTION: Check the generator 1. Engine CAUTION: Engine oil is a major Non-detergent and P-stroke Use Honda 4-stroke oil an equivalent to meet or exceed U.S. automobil SGSF / CCCD. Motor oils classified SGSF / CCCD will show this designation on the con- tainer.
  • Page 11 2. Fuel Remove the filler cap and check the fuel level. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel filter. Your engine is designed to use any gasoline that has a pump octane number of 86 or higher, or that has a research octane number of 91 or higher.
  • Page 12 Gasoline is extremely e Refuel in a well-ventilated flamesorsparksintheareawheretheengineisrefueledorwheregasolineisstored. Do not overfill fuel refueling, make sure Be careful not to spill If any fuel is spilled, Avoid repeated or prolonged KEEP OF REACH GASOLINES CONTAINING If you decide to use a gasoline containing is at least as high as that recommended : one containing...
  • Page 13 3. Air Cleaner Check the air cleaner elemeuts to be sure they are clean and in good coudition. Clean or replace the elements if necessary (page 23). CAUTION: Never run the engine without the air cleaner. Rapid engine wear will result.
  • Page 14: The Engine

    4. STARTING THE ENGINE 1. Turn the AC circuit breaker to the 0F.F position. The generator maybe hard to start if a lood is connected. CIRCUIT BREAKER 2. Move the fuel valve to the ON position FUEL VALVE...
  • Page 15 3. Turn the engine switch to the ON position. ENGINE SWITCH 4. Move the choke lever to the CLOSE position NOTE: Do not use the choke if the engine is warm or the air temperature is high. CHOKE LEVER...
  • Page 16 5. Pull the starter grip lightly until resistance CAUTION: Do not allow the starter gently to prevent damage STARTER GRIP 6. Turn the choke lever to the OPEN position as the engine warms up. CHOKE LEVER is felt,then grip to snap back to the starter.
  • Page 17 To prevent electrical shock Connect a length of heavy Connections for standby a qualified electrician and mustcomply Improper connections into utility lines. or others contact restored, the generator system. CAUTION Limit operation requiring For continuous operation, In either case, the total Most appliance motors...
  • Page 18 Oil Alert System The oil Alert system is designed to prevent engine damage caused by an insufficient Before the oil level in the crankcase falls below a safe amount of oil in the crankcase. limit, the Oil Alert system will automatically shut down the engine (the engine switch will remain in the ON position).
  • Page 19 AC qperation 1. Start the engine. 2. Turn the voltage selector switch to either position as reguired. NOTE: With the voltage sector swich in the “12OV/24OV” 12OV and 240V receptacles but you require more power from the 120V twist-lock to the “120V” position.
  • Page 20 6. STOPFWG THE ENGINE NOTE: To stop the engine in an emergency, turn the engine switch to the OFF position. In normal use: 1. Move,the AC circuit, breaker to the OFF position. AC CIRCUIT BREAKER 2. Turn the engine switch to the OFF position. EN&NE SWITCH...
  • Page 21: Operation

    3. Move the fuel volve to the OFF position. FUEL VALVE High altitude operation At high altitude, the standard Performance will decrease, High altitude performance fuel jet in the carburetor generator at altitudes Honda Generator dealer perform these parburetor Even with suitable carburetor 3.5% for each 1,000 foot increase in altitude.
  • Page 22 Periodic maintenance and adjustment operating condition. Perform following page. Shut off the engine must be rum, make sure the area is well carbon monoxide. CAUTION: Use only genuine Replacement parts which Tool The tools supplied with the generator procedures listed on the following lOxl2mm PLUG HANDLE...
  • Page 23 Maintenance Schedule REGULAR SERVICE PERIOD Perform at every indicated month or IKE;:\ operatmg hour Interval, whrchever Check Engine oil Change Check Air cleaner Clean 1 Sediment Clean 1 Soark ~lua Clean-Readiust Spark arrester Clean Valve clearance Check-Readjust Fuel tank and strainer Clean Check Fuel line...
  • Page 24 Changing Drain the oil while the engine is still warm to assure rapid and complete 1. Remove the oil filler cap and drain plug to drain the oil. 2. Install the drain plug, and tighten 3. Refill with the recommended OIL CAPACITY: 1 .l (1 .I...
  • Page 25 Air Cleaner Service A dirty air cleaner will restrict malfunction, service the air cleaner regularly (page 21). Service more frequently operating the generator in extremely Never use gasoline element. A fire or explosiok CAUTION : Never run the generator result. 1.
  • Page 26 Foam element : Wash the element in a solution of household water, then rinse thoroughly, Allow the element to dry thoroughly. Soak the element in clean engine oil, and squeeze out the excess oil. will smoke during initial start-up Paper element : Tap the element lightly several times on a hard surface to remove excess dirt, or blow compressed Never try to brush the dirt off;...
  • Page 27 Sediment Cup Cleaning The sediment cup prevents the carburetor. If the engine has not been run for a long time, the sediment be cleaned. 1. Move the fuel valve to the OFF position. 2. Clean the cup and fuel filter thoroughly. 3.
  • Page 28 Spark plug service Recommended spark To ensure proper engine operation, of deposits. If the engine not to touch the muffler. Remove the spark plug cap. Clean any dirt from around the spark plug base. Use the wrench supplied in the tool kit to remove the spark plug. Visually inspect the spark plug.
  • Page 29 6. Check that the spark plug washer is in good condition, by hand to prevent cross-threading. 7. After the spark plug is seated, tighten with a spark plug wrench washer. NOTE : If installing a new spark plug, tighten compress the washer.
  • Page 30 Spark Arrester Maintenance If the engine to cool before proceeding. CAUTION: The spark arrester efficiency. 1. Remove the eight 5mm pan screws, and remove the muffler protectors. 2. Remove the 4mm pan screw, and remove the spark arrester SCREWS SCREWS 3.
  • Page 31 mEl!nm When transporting to the OFF position and keep the engine spilled fuel may ignite. Before storing the unit for an extended 1. Be sure the storage area is free of excessive 2. Drain the fuel. a. With the fuel valve OFF, remove and empty the sediment FUEL VALVE SEDIMENT b.
  • Page 32 3. Change the engine oil. 4. Remove the spark plug and pour about a tablespoon cylinder. Crank the engine several revolutions the spark plug. Slowly pull the starter grip until resistance on its compression stroke and both the intake and exhaust valves are colsed. Storing the engine in this position will help to protect 6.
  • Page 33 A. When the engine will not start : 1. Is the engine switch on ? 2. Does the oil alert lamp flash when the starter is pulled ? 3. Is there enough fuel ? 4. Are all loads disconnected 5. Is there a spark at the spark plug ? a.Remove the spark plug cap.
  • Page 34 6. Is gasoline reaching the carburetor To check, place a suitable container and loosen the drain screw. If OK, try to start the engine according EEfm If any fuel is spilled, generator is dry before starting Fuel vapor or spilled fuel may 7.
  • Page 36 Dimensions Power equipment description code Length x Width x Height Dry weight Engine Engine type Displacement (Bore x Storke) 1 Compression Ratio 1 Engine Speed I Cooling System Ignition System Oil Caoacitv 1 Fuel Tank Capacity Spark Plug Generator Rated voltage Rated frequency Rated ampere AC output...
  • Page 37: Service

    Owner Satisfaction Your satisfaction Honda warranty Normally, any problems dea)er’s service been handled to your action: Discuss your problem complaints can be. quickly already been reviewed the dealership If your problem the Power Equipment Motor Co., Inc. American Power P.O. Box 50 Gardena, Telephone: We will need the following...
  • Page 38 MEMO...

Table of Contents