Voltage Selector Switch

The voltage selector switch switches generator output to produce
''120V ONLY'' or ''120V/240V.'' If a 240V appliance is connected to the
4-prong receptacle, the switch must be in the ''120V/240V'' position. If
only a 120V appliance is being connected to any of the 120V 3-prong
receptacles, select the ''120V ONLY'' position.
Select the voltage before starting the engine.
Switch Position
120V/240V: The 120V and 120V/240V receptacles can be used
simultaneously.
120V ONLY: ONLY the 120V receptacles can be used. Do not use the
120V/240V receptacle in this position. The most power will be
available at the 30A 120V locking plug receptacle.

AC Circuit Breaker

The AC circuit breaker will automatically switch OFF if there is a short
circuit or a significant overload at the receptacles.
The AC circuit breaker may be used to switch the generator power ON
or OFF .
AC CIRCUIT BREAKER
CONTROLS & FEATURES
VOLTAGE SELECTOR SWITCH
ON
120V/240V
120V ONLY
OFF