Important Information; Refrigerant; Noise And Vibrations - Danfoss DHP-R Eco Installation Instructions Manual

Table of Contents

Advertisement

1

Important information

This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Cleaning and user maintenance shall not be made by
children without supervision.
Children should be supervised to ensure that they
do not play with the appliance.
The installation must only be carried out by an
authorized installer with reference to applicable
rules and orders and these installation instructions.
This apparatus is not intended for persons (including
children) with reduced physical, sensory or psycho-
logical capacity, or who do not have knowledge or
experience, unless supervised or they have received
instructions on how the apparatus functions from a
safety qualified person.
The heat pump must be located in a frost-free envi-
ronment!
The floor must be able to support the gross weight
of the heating installation.
The heating installation must be placed on a stable
surface.
Before the heat pump is supplied with voltage you
must ensure that the heating system and coolant
system. incl. the heat pump. are filled and bled of
air otherwise the circulation pumps can be dam-
aged.
If the electrician wishes to test his connections
before the above is carried out this should only
done when it has been checked that the heat
transfer fluid and coolant pumps have been discon-
nected.
When filling the coolant system the coolant pump
must be operating but one must ensure that the
compressor and the heat transfer pump cannot
start. The coolant pump can then be run manually
using a separate switch which is located on the
electrical cabinet.
When filling is complete the coolant pump must be
put in Auto mode.
The appliance is intended to be used by expert or
trained users in shops, in light industry and on farms
or commercial use by lay persons
Only spare parts approved by us may be used in this
appliance.
The power supply must be disconnected during
service and before changing parts in the appliance.

1 .1 Refrigerant

The heat pump's cooling system (refrigerant circuit) is
filled with R407C or R134a (depending on version) refrig-
erant.
Work on the refrigerant circuit must only be carried
out by a certified engineer!
Toxicity
In normal use and normal conditions the refrigerant has
low toxicity. However. although the toxicity of the refriger-
ant is low. it can cause injury (or be highly dangerous) in
abnormal circumstances or where deliberately abused.
The refrigerant vapour is many times heavier than air and
in enclosed spaces. below the level of the door for exam-
ple. and in the event of leakage. large concentrations can
occur with the risk of suffocation because of lack of oxy-
gen. Spaces in which heavy vapour can collect below the
level of the air must therefore be well ventilated.
Refrigerant exposed to a naked flame creates a poi-
sonous irritating gas. This gas can be detected by
its odour even at concentrations below its permitted
levels. Evacuate the area until it has been sufficiently
ventilated.
Anyone with symptoms of poisoning from the vapour
must immediately move or be moved into the fresh air.
Work on the refrigerant circuit
When repairing the refrigerant circuit. the refrigerant
must not be released from the heat pump – it must be
destroyed at a special plant. Draining and refilling must
only be carried out using new refrigerant (for the amount
of refrigerant see manufacturer's plate) through the serv-
ice valves. All warranties from Danfoss Heat Pump´s AB
are void if. when filling with refrigerant other than R407C
or R134a. it has not been notified in writing that the new
refrigerant is an approved replacement refrigerant
together with other remedies.
Scrapping
When the heat pump is to be scrapped the refrigerant
must be extracted for destruction. The local regulations
for treatment of refrigerant must be followed. See the
relevant Swedish Environmental Protection Agency refrig-
erant statutes.

1 .2 Noise and vibrations

From the sound and vibration point of view it is important
that the pipe mountings in the ceiling and walls are made
with vibration damping fastenings and that the holes for
lead-ins in the walls are made as large as possible so that
sound and vibration do not spread.
If the house has poor acoustics. special care must be
taken so that the vibrations do not spread into the build-
ing.
In such cases no mountings may be made in the house
near the heat pump. All mountings must be in free stand-
ing constructions. which themselves are in vibration
damping material such as Solodyn.
In those cases where the coolant side must be mounted
to the building. flexible hoses should be used. although
not the same type as the heat transfer pipes. Flexible
hoses for the heat transfer and hot gas must be extra
long (600 mm or longer) and connected at 90°. If one
suspects that the floor on which the heat pump is located
may transfer vibration to the rest of the building. the heat
pump must be positioned on Solodyn pads. These pads
must be weight adapted. Always consult the representa-
tive from Danfoss Heat pump´s AB in these cases.
VMIFI102
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents