Specifications - Transmitter Solutions DOLKSS1KB Programming & Installation Manual

Self contained digital access control keypad
Hide thumbs Also See for DOLKSS1KB:
Table of Contents

Advertisement

Set Authorization Code
to toggle [on/off] (partial
entry)

SPECIFICATIONS

Operation Voltage:
12V-24V AC/DC, No jumper is required for voltage selection
Operation Modes:
Single User Mode, Auto, or Manual Code Entry
Multi-User Mode, Auto, or Manual Code Entry
User Code Combinations:
Single User Mode: 10,000
Multi User Mode: 111,110,000
Multi User Mode: 100 user codes for door open (User number: 00-99)
Access Lock Mode: 10 user codes for Access Lock codes (User number: 0-9)
Egress input:
Normally open
Relay Output Contacts:
Normally Closed and Normally Open Dry Contacts, 5A / 30VDC Max. Rating
Auto Refreshing Time During Code Entry:
Each digit maximum entry time limit – 10 seconds
Each code maximum entry time limit – 30 seconds
Dimensions: 4 5/8(H)" x 2 7/8(W)" X 1 7/8(D)"
Weight: 5.5oz net
Specifications are subject to change for modification without notice
BASIC WIRING EXAMPLE – Basic wiring of a stand-alone door lock
AD-1312 OR AP-960
AD-2312
(INSIDE THE HOUSE)
12 24V
-
AC / DC
POWER
SUPPLY
EGRESS BUTTON
N.O.
MORE EGRESS
BUTTONS CAN
N.O.
BE CONNECTED
IN PARALLEL
52 #
+
-
OUTPUT 1
EG
12 24V
N.C. C. N.O.
IN
OUTPUT RELAY
N.C. N.O.
N.O. Output for Fail-secure Lock
OR
N.C. Output for Fail-safe Lock
ELECTRIC LOCK
1N4004
Entering [The first 2 digits of an
Authorization Code, #] will toggle Access
Lock on and entering the full Authorization
Code will toggle Access Lock to off.
CATHODE

Advertisement

Table of Contents
loading

Table of Contents