Device of this mark is a trademark OPERATION MANUAL of Sharp Corporation. Plasmacluster is a registered trademark or a trademark of Sharp Corporation. IG-CL15A The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm...
*Replacement is required approximately every 2 years (17,500 hours) when operated 24 hours a day. IG-CL15A will stop operating after about 26 months (19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced. Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please read this manual carefully before using Plasmacluster Ion Generator.
• DO NOT use the unit near gas appliances or fireplaces. • If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp Authorized Service Center or similarly qualified person in order to avoid a hazard.
PARTS NAME FRONT Control Panel Unit Replacing Light Filter Clean Light Air Outlet Filter Reset Button (Press 3sec) Mode Button Fan Speed Indicator HIGH BACK Louvers are movable Louver Handle Cleaning Brush Filter (Air Intake) Plasmacluster Ion Generating Unit Plug Date Label Power Cord...
INSTALLATION POSITION Place the main unit on a smooth, stable surface in a room, and insert the plug into an electric socket. Installation Guidance DO NOT USE the below items Leave at least 10cm of clearance behind the unit. near the unit UPSIDE more than 60cm silicone-containing products* SPRAY...
CLEANING AND MAINTENANCE WARNING: When cleaning the unit, be sure to first unplug the power cord, and never handle the plug with wet hands. Electric shock and/or bodily injury may occur as a result. MAIN UNIT Every month or more often if necessary Wipe with a dry soft cloth.
CLEANING AND MAINTENANCE PLASMACLUSTER ION GENERATING UNIT Every 6 months or more often if necessary *When cleaning the Plasmacluster lon Generating Unit, be sure to turn off the main unit, unplug the power cord, and never handle the plug with wet hands. Remove dust of the needle electrode by using the cleaning brush.
REPLACEMENT OF PLASMACLUSTER ION GENERATING UNIT Plasmacluster Ion Generating Unit Model IZ-CCL15E * Before replacing the Plasmacluster Ion Generating Unit, be sure to turn off the main unit, unplug the power cord, and never handle the plug with wet hands. Remove the filter.
• Remove dust from the needle electrode. (See page E-6) (blue) (orange) If the lights are still flashing after cleaning filter, unplug and contact the store you purchased or Sharp service center. • Filter is getting dirty. Clean the filter. Lighting After cleaning the filter, press Filter Reset (orange) Button for 3 seconds.