Spray Settings
The handset has three different spray actions: Start, Soothe and Massage and an Eco setting. To adjust the
spray setting turn the spray plate as follows:
1. Start
- Water flows from the outer set of holes.
To select the Start setting, turn the spray plate
anticlockwise from the full clockwise position
until it clicks once.
2. Soothe
- Water flows from the middle set of holes.
To select the Soothe setting, turn the spray plate
anticlockwise from the full clockwise position until it
clicks twice.
3. Massage
- Water flows from the inner set of holes.
To select the Massage setting, turn the spray plate
anticlockwise from the full clockwise position until
it clicks three times.
4. Eco
- Water flows from the outer set of holes at a
reduced flow rate.
To select the Economy setting, turn the spray
plate fully clockwise.
22
CFI230G
Spray Plate
Check the wall channel is vertical and mark
through the
3
holes 'A'
Drill
3
x 6mm holes
A
Fit plugs
Loosely fit screws
Seal behind channel
and tighten screws
A
STEP
5
Slide glass panel into slot in tray "A' and fit
jamb into wall channel 'B'
B
A
STEP
7
Fit the splash guard to the bottom of the panel.
Note: lip faces to the outside of Enclosure
and cutout is towards the wall end of the glass
STEP
On the inside of the enclosure. pull the rubber
strip away from the wall jamb
STEP
8
CFI230G