CONNECTION DIAGRAM
MODELS 7K - 9K -12K
Indoor unit
Terminal
Yellow/Green
3
Brown
2
Power cable
Blue
1N
Check that the colours of the connections on
the outdoor unit and the terminal block are
not the same as those on the indoor unit.
OUTDOOR UNIT CONTROL CABLE
(inside)
PFor connections between the indoor and outdoor unit
exceeding 5 metres (standard cable supplied), two quick
connectors are supplied (see the figure).
18
English 11/2002
Outdoor unit
Terminal
Yellow/Green
3
Brown
2
Blue
1N
Models 7K-9K-12K-17,3K-23,5K
Quick connectors
Models 7K-9K
Models 12K-17,3K-23,5K
MODELS 17.3K-23.5K
Indoor unit
Terminal
Yellow/Green
Brown
3
Red
2
Power cable
Blue
1N
(outside)
All the electrical connections must be performed
by specialist technicians, in accordance with the
legislation in force in the country concerned.
Respect the sequence and the colour of the
cables when using the two connectors supplied.
Outdoor unit
Terminal
Yellow/Green
Brown
3
Red
2
Blue
1N
SINGLE SPLIT