gledhill BoilerMate CP 120 Design, Installation & Servicing Instructions page 7

Boilermate cp series mains pressure hot water thermal store for use with central plant boilers
Table of Contents

Advertisement

The minimum
clear opening in
front of the
Maintenance
appliance to be
at least the
same depth as
the appliance.
*Min maintenance
access to comply with
the Water Regulations
(ballvalve model only)
Top up
cistern
B
BoilerMate CP
E
280
Top up
cistern
access
Model
BMCP120
BMCP150
BMCP180
BMCP220
Note: The Appliance dimensions above do not
allow for the100mm high installation base.
The following table of minimum cupboard
dimensions only allow the minimum space
required for the appliance (including the F & E
cistern). Any extra space required for shelving
etc in the case of airing cupboards etc must
be added.
Model
BMCP120
BMCP150
BMCP180
BMCP220
Note: The above dimensions are based on the
Appliance and the Top up cistern (fi tted with a
ballvalve) being in the same cupboard. If the
manual fi ll method is chosen the heights can
be reduced by 125mm.
If pipework needs to rise vertically adjacent
to the appliance the width/depth will need
increasing to accommodate this.
The cupboard door
opening will need
to take into
account the various
sizes of appliances.
Figure 1.3
Page 7
DESIGN
Appliance Dimensions
Height
Width
A
B
1075
530
1145
560
1275
560
1575
560
Minimum Cupboard Dimensions
Height
Width
D
E
1825
570
1895
600
2025
600
2325
600
TECHNICAL DATA
Depth
C
595
630
630
630
Depth
F
610
645
645
645

Hide quick links: