2.7.2 Digital EXtra Device Port (Digital XDP) Connection
With KX-T7600 Series DPT
Using an EXtra Device Port
To DLC8/DLC16 card
To DLC4 port on the
DMPR card
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Back View of DPTs
TO TEL
TO MAIN UNIT
/ PABX
118
Installation Manual
Master DPT
Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
Master DPT
To DLC8/DLC16 card
To DLC4 port on the DMPR card
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Slave DPT
Maximum Distance
30 m
50 m
60 m
50 m
Slave DPT
TO MAIN UNIT
/ PABX