Troubleshooting Guide - Luraco iROBOTICS 6 User Manual

Ultimate medical massager
Hide thumbs Also See for iROBOTICS 6:
Table of Contents

Advertisement

LED Color/Function
Power ( Blue)
Remote Control (Yellow)
Up/Down Sensors (Red)
Overloaded (Red)
MAINTENANCE INSTRUCTION
This product does not require any lubrication for the mechanical parts in the system.
Use only leather care products for cleaning and maintaining the leather.
Problem/Issue
Does not work after powered
up
Sounds like tapping or
humming sounds
Roller height changes
Abnormal sounds while
working
Suddenly stops working
Can not recline the chair
Can not restore position after
reclining
Remote control is hot or
overheats
Abnormal overheating from
power wire or plug
Blue is good. This LED should be on continuously
If this yellow LED is on, it means that remote has technical
issue
If this red LED is on, it means that vertical limit sensors are
having a problem
If this red LED is on, it means that mechanism up/down
motor is overloaded
Trouble Shooting Guide
Possible Cause
1. Power switch is not turned on
2. Bad connection between power
plug and socket
3. Massage remote is not turned on
4. Broken power cord or plug
5. Bad fuse
6. Control unit does not function
properly
Sounds from air pump, motor, or other
mechanical parts
Rollers work alternately
Maybe from over working the massage
mechanism
1. Bad power connection
2. Auto program timer is up
Obstruction-be sure that chair is
allowed enough room to fully recline
Bad connection.
Over recommended usage
1. System is overloaded
2. Other unknown causes
Meaning
Trouble Shooting Method
1. Turn power switch On (on the
back)
2. Connect power cord again
3. Press power button on remote
4. Request manufacturer or service
technician to replace power cord
5. Replace the fuse with exact
specifications
6. Contact Technical Support of the
manufacturer if it continues.
Normal phenomenon
Normal phenomenon
1. Cut down on usage (no more
than 20 minutes per session)
2. Contact Technical Support of the
manufacturer if it continues
1. unplug and reinsert power cord to
the chair
2. Normal operation
Stop chair operation, and move
obstruction
Contact Technical Support of the
manufacturer if it continues
Use only 20 minutes per session
1. Cut down usage (no more than
20 minutes per session)
2. Contact Technical Support of the
manufacturer if it continues
15

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iROBOTICS 6 and is the answer not in the manual?

Questions and answers

Table of Contents