5.6.5. n (Memory Select)

Function: To change memory number. It is only available in steady state.
Format: ID n [ Sel ]
Sel
Select memory number
0 – 15
Omitted
Response: ID n sel
sel
selected current memory number
0 – 15
5.6.6. nE
(Memory Save)
Function: To save current memory selection. On next start up, the memory number is selected
according to the saved data. If you change memory selection by remote control, the
status is automatically saved. If you change input port selection by remote control, the
memory selection might change. It is only available in steady state.
Format: ID nE
Response: ID nE
5.6.7. nA
(Analog Input, Memory Select)
Function: To change memory number with changing input port to analog at the same time. It is
only available in steady state.
Format: ID nA [ Sel ]
Sel
Select memory number
0 – 15
Response: ID nA sel
sel
selected current memory number
0 – 15
5.6.8. nD
(Digital Input, Memory Select)
Function: To change memory number with changing input port to digital at the same time. It is
only available in steady state.
Format: ID nD [ Sel ]
Sel
Select memory number
0 – 15
Response: ID nD sel
sel
selected current memory number
0 – 15
VS-SH10U Set-up and Installation Manual
Memory number
Returning current setting value.
Memory number
Memory number
Memory number
Memory number
Memory number