5.6. Control commands

5.6.1. vP
(Power)
Function: To control power supply
Format: ID vP [ Power ]
Power
Control power on/off
0
1
Omitted The projector returns current mode.
Response: ID vP mode
Current power control status
mode
0
1
[Note]
After completion of turning on, it is desirable to issue other control command with confirming that
start-up process is finished and system is steady state. You can confirm the processing state by
[vS] command.
Sequence of turning on process
External controller
01vP1 ¥r
01vP1 ¥r
01vS ¥r
01vS18 ¥r
01vS ¥r
01vS14 ¥r
01i0 ¥r
01i0 ¥r
VS-SH10U Set-up and Installation Manual
The projector moves to the stand-by mode when it is in the
normal mode or the start-up process.
The projector moves to the start-up process when it is in the
stand-by mode.
Termination process, stand-by mode
Start-up process, normal mode
Projectors
47
Sequence of turning off process
External controller
01vP0 ¥r
01vP0 ¥r
01vS ¥r
01vS4 ¥r
01vS ¥r
01vS2 ¥r
Projectors