External controller
100 msec or less
50 msec or more

5.5. Command return value

Projectors return command execution results with ASCII character strings. A result string consists
of an ID number, command name and zero or more return values. A CR code is added at the end
of each result string. The ID number and the command name shall not be delimited. The ID
number represents unit ID by two decimal digit ASCII characters.
When the projector receives a command with a command ID "00", it will return the result string. If
the projector receives an undefined command, it will not return any result string. If the master
function is not set effective, it will not return any result string.
The result strings which are returned in response to the command with the ID number "00" will
contain the ID number "00".
ID Command [ Parameter1 ]¥r
Example: 01vP1 ¥r
Note: "¥r" stands for a CR code (0Dh).
Attention
An inexecutable error may be returned when there is OSD indication such as a remote controller
adjustment menu.
Projectors
01NP1¥r
01NP1¥r
01i0¥r
01i0¥r
00NP0¥r
00NP0¥r
Analyzing and executing the command within 700 msec.
Analyzing and executing the command within 700 msec.
When command ID "00" is sent, only the
projectors whose master function is set
effective will respond to the command.
(Note) ¥r stands for a CR code.