Installation Requirements; Operation Instructions - Atmor 900 series Installation Manual

900 series instant water heater
Table of Contents

Advertisement

OPERATION INSTRUCTIONS

1. Your new Instant Water Heater is flow activated. Simply place one or both switches in the ON position
and turn on the hot water tap. You will need to allow at least 1.5 liters per minute to flow through the unit
in order to activate the Instant Heating System. Run water through the heater for a few minutes.
2. Be sure to every so often clean the spray head of sediment to assure a smooth water flow.
3. Be sure to every so often clean the incoming water filter.
4. The maximum operating water pressure is 8 atmospheres or 115 PSI. This is well above the usual 3
atmospheres or 40 PSI most municipal water systems provide.
5. Be sure to install your Instant Water Heater in a heated location. It cannot be installed where temperatures
drop below freezing.
6. There are two ways to adjust the hot water temperature. One is by adjusting the flow, the other is by
changing the electrical settings on the unit. The slower the flow, the more time the unit has to heat the
water, resulting in higher water temperatures. Adding more rings to the water flow restrictor will limit the
flow and increase the output water temperature. You may choose the low, medium or high settings on
the heater, as required to achieve the water temperature desired.
Setting 0/OFF: No heating, lamp will not light.
Setting 2: Medium heating, lamp 2 will light.
For 220V - 240V 3.5kW unit only positions 0 & 1 are available.
7. During the summer, it is recommended using only setting 1 or 2 for device with 220V-240V 13kW output.

INSTALLATION REQUIREMENTS

A. A separate electrical line is required.
B. The device must be connected to a separate circuit breaker.
C. The recommended electrical cable for feeding the device, see table I (next page).
Device below a sink with 110V up to 3.5kW output
and 220V-240V 3.5kW-8.6kW output
1
1
L
L1
E(G)
E(G)
N
L2
Device below a sink with 220V - 240V 8.6kW-10.6kW output
1
L1
L
L2
N
E(G)
E(G)
4
1
3
4
5
8
7
Setting 1: Low heating, lamp 1 will light.
Setting 3: Maximum heating, both lamps will light.
1. Terminal block
2. Thermal cut-out with reset
3. Thermal cut-out
4. Relay
5. Light
6. Switch 0- Off
7. Heating element
8. Read sensor
1. Terminal block
6
2. Thermal cut-out with reset
3. Thermal Cut out
4. Relay
5. Switch 0- Off
6. Heating element
7. Read sensor
8. EARTH(G) Connection in
the heating canister
(Option) 1- Low
1- Low
2- Medium
3- High

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

At900-04At900-06At900-08At900-10At900-13At900-03

Table of Contents