5.4.2.11

Self-diagnosis function setting

This self-diagnosis function setting function is used to enable or disable error detection by each
sensor. When using this, note that error detection can temporarily be disabled or enabled for
troubleshooting and enabled error detection can make settings for, among printer engine operation
items, items that require expert knowledge for the items to be handled. After error detection is used,
be sure to change the setting for the error detection back to its default.
1. Enter the self-diagnostic mode (level 1), press the MENU+ or MENU- key until ENGINE PA-
RAMETER SET2 appears on the upper display, and press the Enter key (the MENU+ key
increments an item, and the MENU- key decrements an item).
2. Press the MENU+ or Menu- key until an item for which a setting will be made is shown on the
upper display.
3. Pressing the ENTER key enables the selection of a setting on the lower display, blinking the
item on the upper display and, on the lower display, a setting currently set for the item (the
blinking mean that they can be set by pressing MENU+ or MENU- key).
4. Press the MENU+ or MENU- key to display the setting that will be set for the item.
5. While that setting is blinking, concurrent use of the CANCEL and ONLINE keys accepts the
setting, restoring the display of step 2.
6. Repeat steps 2 to 5 if necessary.
7. Press the BACK key to end the setting (the display of step 1 is restored).
Print Density Adjustment Test Items
Display
TONER SENSOR
BELT UNIT CHECK
ID UNIT CHECK
UP/DOWN SENSOR
REG ADJUST ERROR
42615101TH Rev.8
Setting
Description of Setting
ENABLE
Performs detection
DISABLE
Does not perform detection
ENABLE
Performs checking
DISABLE
Does not perform checking
ENABLE
Performs checking
DISABLE
Does not perform checking
ENABLE
Performs detection
DISABLE
Does not perform detection
ENABLE
Makes operation a pause
DISABLE
Does not make operation a
pause.
Oki Data CONFIDENTIAL
is default
Function
Enables or disables toner sensor
operations.
Enables or disables the
checking of belt installation.
Enables or disables the checking
of image drum installation.
Enables or disables image drum
up/down sensor operations.
Enables or disables the function
of an error pause controlled
based on each color registration
value detected.