Oki C3200n Service Manual page 185

Hide thumbs Also See for C3200n:
Table of Contents

Advertisement

Message
Power off/on
901:Error
902:Error
Power off/on
903:Error
904:Error
Service call
905:Error
Service call
906:Error
Service call
907:Error
Service call
908:Error
Loader V. xx.xx
PW-LSI ERROR
Loader V. xx.xx
S-RAM ERROR
42615101TH Rev.8
Table 7-1-2 Service Call Error (6/7)
Cause
Short or open in
Is belt thermistor cable setting
belt thermistor
proper?
detected.
Does error reoccur?
Abnormal tem-
Is belt thermistor cable setting
perature detected
proper?
by belt thermistor
(high-temp or low
Does error reoccur?
temp.)
An open error of
frame thermistor
Does error reoccur?
(defective ther-
mistor or improper
connection)
detected.
A short circuit
error of frame
Does error reoccur?
thermistor (defec-
tive improper)
detected.
A high tempera-
ture error (over
Does error reoccur?
150°C) of frame
thermistor de-
tected.
A low temperature
error (below
Does error reoccur?
[environmental
temperature
minus 10]°C) of
frame thermistor
detected.
A high-voltage
Is the cable between the PU
power unit
board and the high-voltage
interface error at
power unit connected properly?
initialization.
Is there poor contact?
A PU board
SRAM error.
Does error reoccur?
Error Description
Oki Data CONFIDENTIAL
Solution
No
Connect cable set
properly again.
Yes
Turn power ON again.
Yes
Replace belt
thermistor.
No
Connect cable set
properly again.
Yes
Turn power ON again.
Yes
Replace belt thermistor
and leave aside for 30
min. Then turn power
ON again.
Turn power ON again.
Yes
Replace the fuser unit.
Turn power ON again.
Yes
Replace the fuser unit.
Turn power ON again.
Yes
Replace the fuser unit.
Turn power ON again.
Yes
Replace the fuser unit.
No
Connect the cable
properly.
Yes
Check the high-voltage
system for poor
contact.
No
Replace the high-
voltage power unit.
Turn on the printer
again.
Yes
Replace the PU board
(PRN).
185 /