REMOVING THE ELECTRONIC CONTROL BOARD
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Unplug the clothes vitalizer or disconnect
the power.
2.
Remove the twelve T-15 Torx screws from
the top component cover and remove the
cover from the unit (see page 5-2).
The component described on this page is
shown below.
Electronic Control Board
3.
Pull the two ribbon cables out of the con-
nectors.
2 Ribbon Cables
4.
Remove the rubber band from the locking
arms of the electronic control board hold-
ers.
Locking Arm
5.
Push the two locking arms outward and
slide the electronic control board out of the
holders, then place a piece of heavy paper
or cardboard under the board, and set it on
top.
6.
Disconnect the four wire connectors from
the electronic control board pins.
4 Wire Connectors
REASSEMBLY NOTE: The ribbon cable con-
nectors are polarized with a tab so that they
cannot be reversed. Slide the cable connector
tab into the board connector slot when rein-
stalling the cables.
5-7
Locking Arm
Rubber Band