5-1. PICTURE QUALITY ADJUSTMENT

5-1-1. Preparation

1. Set in the service mode.
2. Set respective items as follows.
Adjustment Condition
DRC-MF
PICTURE MODE
3D-NR MODE
ECO MODE
Main Picture adjustment : TWIN OFF
Sub Picture adjustment
Category
Item
PIC
00
PIC
01
COL
05
PIOF
LUMA
01
GAMM
06
BLK
COLR
00
CLOF
01
HUOF
02
RDRV
03
GDRV
04
BDRV
05
RCUT
06
GCUT
07
BCUT
09
DCOL
3. Connect the oscilloscope probe to the following point on the
UG board.
Measurement Point
UG Board CN1504 :
A5
pin
G
B5
pin
B
Note : After the adjustment 5-3. Picture Quality Adjustment,
these adjustment parameters must be recovered to the
original condition.

ELECTRICAL ADJUSTMENTS

: DRC1250
: HI-FINE
: OFF
: OFF
: TWIN
Data
100
50
0
0
0
3
3
31
31
31
31
31
31
0
t
VG
t
VB
SECTION 5
Original Condition
DRC-MF
ICTURE MODE : HI-FINE
3D-NR MODE
ECO MODE
Category
PIC
LUMA
COLR
MCP
MID2
– 79 –
KP-FWS57M90
: DRC1250
: OFF
: OFF
Item
00
PIC
60 (HI-FINE)
01
COL
50 (HI-FINE)
05
PIOF
5 (HI-FINE)
01
GAMM
6 (HI-FINE)
06
BLK
0 (HI-FINE)
00
CLOF
0
01
HUOF
3
03
GDRV
35
06
GCUT
31
09
DCOL
3
14
ABLT
7 (Normal/V-comp)
0 other
02
BCOL
5 (TWIN)
RM-1007