1-4. SELF-DIAGNOSTIC SCREEN DISPLAY

For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confirmed, it is possible to
bring up past occurrences of failure for confirmation on the screen:
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
Self-Diagnosis screen display

1-5. HANDLING OF SELF-DIAGNOSTIC SCREEN DISPLAY

ON SCREEN
(
DISPLAY
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen
SELF DIAGNOSTIC
2 OCP
3 OVP
4 V STOP: 0
5 AKB
6 LOW-B : 0
After you have completed the repairs, clear the result display to "0".
[Clearing the result display]
To clear the result display to "0", press button on the remote commander sequentially as shown below when the diagnostic screen is being
displayed.
(It will indicate "CLEAR" on the screen.)
[Quitting Self-diagnostic screen]
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
5
(DIGIT 5)
(VOLUME –)
)
*
* : Note that this differs from entering the service mode (volume +)
: 0
7
H STOP : 0
: 0
8
A PRT
9
Z DET
: 0
10 HV PRT : 0
101 WDT
102 WDT PF : 24
Press "8" button
(POWER)
Number "1 "
means a fault was detected one
: 1
time only.
: 0
Number "0 "
: 0
means that no fault detected.
,
Press "-" button
(The "CLEAR" display change to red color.)