ADJUSTING THE TERMINAL DISPLAY
This section contains detailed instructions for each adjustment
mentioned in Table
4-1 and a cross reference for the test pattern
that you should use when making that particular adjustment.
See
Figure 4-2 to identify adjustment locations on the terminal PCB.
The order in which we have listed adjustments in this section
corresponds to the order of full alignments listed in Table
4-1.
To perform a full alignment, make all adjustments in the order
that follows.
Figure 4-2
Adjustment Locations
L202
~~
VR204
Vertical Hold
On certain early units the vertical hold adjustment is labeled
VR301 on the terminal PCB.
On most units, VR301 is replaced with
a fixed resistor.
If you can adjust vertical hold, use display
test pattern O.
Adjust VR301 until the display is steady and doesn't roll.