Figure 2-10
Discharging the Anode Before Removal
Aligator Clips
Terminal Chassis
4.
Slip the blade between the anode cap and the anode.
Touch
the blade to the wire anode leads under the cap.
Listen for
a po ppi ng or crac kl ing so und.
5.
Remove the anode lead.
To discharge the anode before installation
(See
Figure 2-11),
follow these steps:
1.
Ground the shaft of an insulated flate-bladed screwdriver.
2.
Touch the blade of the screwdriver to the anode.
a popping or crackling sound.
Listen for
3.
Install the CRT.