Tiger Video Routing Switcher
Connector Interface Board
Remote Control Panel Connectors (PANEL PORTS)
These 3-contact connectors provide RS-485 serial communication interfaces using the PESA RCP
Protocol (Document No. 81-9062-0300-0). See Figure 2 for an orientation view showing contact
locations.
The PANEL PORT connectors are connected to PESA Remote Control Panels with daisy-chained
cables constructed with 3-contact connectors (Part No. 81-9029-0780-0) and shielded, twisted-pair
audio cable (Part No. 81-9028-0043-2, Belden 8451, or equivalent) as shown in Figure 3. The
connector body has an integral strain relief which requires the use of a nylon cable tie which is
included with the connector. If this cable tie is not available, Part No. 81-9021-0028-8 may be used.
Figure 2. PANEL PORT Connectors
Figure 3. RS-485 Serial Cable
Chapter 2 – Installation
9