Master/Slave Mode; Ethernet Connections; Ethernet Connections Diagram - Chauvet Nexus 4x4 User Manual

Hide thumbs Also See for Nexus 4x4:
Table of Contents

Advertisement

Master/Slave
Mode
Ethernet
Connections
Ethernet
Connections
Diagram
Nexus™ 4x4 User Manual Rev. 4
In Master/Slave mode one Nexus™ 4x4 product (the master) controls one or more Nexus™
4x4 products (the slaves) without a DMX controller. The master Nexus™ 4x4 is set to an auto
program, static color, or color macro and sends DMX signals to the slaves. During
Master/Slave operation, the slave products operate in unison with the master. For more
information, see Master/Slave.
· Do not connect a DMX controller to the DMX chain when operating Nexus™ 4x4
products in Master/Slave mode, because signals from the master and the DMX
controller will conflict and cause erratic behavior in all the products.
· Master/Slave operates via DMX ports only. The Neutrik® etherCON® ports cannot be
used for Master/Slave mode.
For more information about DMX, see the CHAUVET® DMX primer, available at
www.chauvetlighting.com.
Ethernet connections link Nexus™ 4x4 to routers and each other through their Neutrik®
etherCON® ports. Ethernet connections are for running TCP/IP-based control system, such as
Art-Net™ and Kling-Net. All Neutrik® etherCON® ports can be either input or output ports,
and panels can be linked together, but the start of each chain must be a router port.
Do not connect Nexus™ 4x4 to the WAN port of the router.
Computer or Controller
Running TCP/IP-based
protocol, such as
Kling-Net or Art-Net™
NOTE: Do Not Use WAN Port On Router!
Router
Nexus™ 4x4 Panels
Setup
More
Products
-11-

Advertisement

Table of Contents
loading

Table of Contents