Performing Automatic Teaching
The bar code and 2D-code parameters can be automatically set with commands from an external device, such
as a PLC, based on the image that was just input when the line process was changed.
Inspection item
Bar code
2D-code
Note
• Application is possibly only from the Run Mode.
• If the parameter is applicable to more than one inspection item, automatic teaching will be performed for all appli-
cable inspection items.
• While master data is registered with teaching during an automatic registration from a display, no master data is
registered with automatic teaching by IN1.
Settings
[In/Out] - [I/O setting] - [I/O terminals] - [Input] - [Input mode]
Press [Expand mode].
Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Yellow
OUT1 (BUSY)
126
Controlling/Outputting in Parallel
Re-registered data
Code type, read direction selection, reverse on/off
Code type, reverse, code color (DataMatrix, PDF417 only), shape (DataMatrix)
State
Description
OFF
ON
Command parameter for automatic teach-
OFF
ing
OFF
OFF
ON
Command input for automatic teaching
--
Processing in progress (default)
The signals shown at the left
are used.
Refer to the following
information for signal wiring.