2-3 Installation

Installing the Sensor

Installation Procedure

1
Align the tabs on one side of the Mounting Bracket with
the slot on the Sensor.
The FQ-XL Mounting Bracket can be attached to the back,
side, or front of the Sensor.
2
Press the Mounting Bracket onto the Sensor until the oth-
er tabs click into place.
3
Use the following optical charts to check the field of view
and installation distance of the Sensor so that it is mount-
ed at the correct position.
Tightening torque (M4): 1.2 N·m
Horizontal field of view
Installation distance (L)
FQ-CR10010F, FQ-CR15010F
Installation distance (L) (mm)
55
45
35
6
8
10
Horizontal field of view (mm)
FQ-CR10050F, FQ-CR15050F
Installation distance (L) (mm)
210
130
50
0
20
Horizontal field of view (mm)
FQ User's Manual
The optical chart indicates the horizontal
Vertical field
field of view. The vertical field of view will
of view
be approximately 60% of the horizontal
field of view.
Note: The tolerance is ±10%.
Installation distance (L) (mm)
12
14
Installation distance (L) (mm)
40
60
FQ-CR10100F, FQ-CR15100F
1,000
600
200
0
100
200
Horizontal field of view (mm)
FQ-CR10100N, FQ-CR15100N
400
0
0
200
Horizontal field of view (mm)
Mounting
Bracket
300
400
21

Installation