Setting the Data To Be Logged
Use the following procedure to set the statistical data, image data, and measurement data that will be logged.
[In/Out]  [Log setting]
1
Press the data for which to change the logging pa-
rameters.
2
Change the logging parameter and then press [Back].
Item
Statistical Data
Image logging
Data logging
Note
The logging parameters for image data and measurement data are the same as those for file logging.
Starting Logging
Logging will be started as soon as the data to be logged has been set.
If the settings are saved, logging will start automatically the next time the power supply is turned ON.
Checking the Results of Logging
The results of logging can be checked using the trend monitors, histograms, or statistical data.
p. 82
Use the following menu command to check the measurement images.
(Setup Mode) 
Deleting Logged Data
The logged data will be deleted when the power supply to the Sensor is turned OFF or the scene is changed.
The logged data can also be deleted without turning OFF the power supply.
• Setup Mode
[In/Out]  [Log setting]
1
Press [Delete Log].
100
Logging Measurement Data and Image Data
Statistical data, such as the number of measurements, the number of NG overall judgements, and the
NG rate, since the power supply was turned ON will be logged.
• ON: Statistical data will be displayed (default).
• OFF: Statistical data will not be displayed.
These are the same as for file logging.
Logging All Data (File Logging): p. 96