Accuracy (cont'd)
AC Current (AC + DC Current on DM-830A and DML-430A Only)
Accuracy at
Range
50 to 60 Hz
600.0 µA
± (0.6% + 0.3 µA)
6000 µA
± (0.6% + 3 µA)
60.00 mA
± (0.6% + 0.03 mA)
600.0 mA
± (1.0% + 0.3 mA)
6.000 A
± (0.8% + 0.006 A)
10.00 A
± (0.8% + 0.06 A)
10 A continuous, 20 A for 30 sec. maximum with 5 minute cool down.
DC Current
Range
600.0 µA
6000 µA
60.00 mA
600.0 mA
6.000 A
10.00 A
10 A continuous, 15 A for 30 sec. maximum (20 A for DML-430A) with 5 minute cool down.
Line Level Frequency
Function
60.00 mV
600.0 mV
9.999 V
99.99 V
999.9 V
600.0 µA
6000 µA
60.00 mA
600.0 mA
6.000 A
10.00 A
22
Accuracy at
40 to 1 kHz
± (0.8% + 0.4 µA)
± (0.8% + 4 µA)
± (0.8% + 0.04 mA)
± (1.0% + 0.4 mA)
± (0.8% + 0.006 A)
± (0.8% + 0.06 A)
Accuracy at 50 to 60 Hz
± (0.2% + 0.4 µA)
± (0.2% + 4 µA)
± (0.2% + 0.04 mA)
± (0.2% + 0.4 mA)
± (0.2% + 0.004 A
± (0.2% + 0.04 A)
Sensitivity (Sine RMS)
40 mV
60 mV
2.5 V
25 V
100 V
45 µA
600 µA
40 mA
60 mA
4 A
6 A
Burden Voltage (typical)
(all frequency ranges)
0.08 mV/µA
2.1 mV/mA
0.02 V/A
Burden Voltage (typical)
(all frequency ranges)
0.08 mV/µA
2.1 mV/mA
0.02 V/A
Range
15.00 Hz to 50.00 kHz
15.00 Hz to 50.00 kHz
15.00 Hz to 10.00 kHz
15.00 Hz to 10.00 kHz
15.00 Hz to 10.00 kHz
15.00 Hz to 3.000 kHz
15.00 Hz to 3.000 kHz
15.00 Hz to 3.000 kHz
15.00 Hz to 3.000 kHz
15.00 Hz to 3.000 kHz
15.00 Hz to 3.000 kHz