Patton electronics SmartNode 4900 Getting Started Manual

Patton electronics SmartNode 4900 Getting Started Manual

Ipchannel bank analog access routers
Hide thumbs Also See for SmartNode 4900:
Table of Contents

Advertisement

Quick Links

For Quick
Start Installation
SmartNode 4900
IpChannel Bank
Getting Started Guide
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com
Document Number: 13217U1-001 Rev. D
Part Number: 07MSN4900-GS
Revised: January 5, 2007
VoIPon
www.voipon.co.uk
sales@voipon.co.uk
Tel: +44 (0)1245 808195
Fax: +44 (0)1245 600030

Advertisement

Table of Contents
loading

Summary of Contents for Patton electronics SmartNode 4900

  • Page 1 For Quick Start Installation SmartNode 4900 IpChannel Bank Getting Started Guide Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com Document Number: 13217U1-001 Rev. D Part Number: 07MSN4900-GS Revised: January 5, 2007 VoIPon www.voipon.co.uk sales@voipon.co.uk...
  • Page 2 Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or...
  • Page 3: Summary Table Of Contents

    Summary Table of Contents General information............................15 Applications overview............................ 21 Hardware installation............................ 24 Getting started with the SmartNode 4900 Series................... 36 LEDs status and monitoring ......................... 46 Contacting Patton for assistance ........................48 Compliance information ..........................51 Specifications ..............................54 Port pin-outs ..............................
  • Page 4: Table Of Contents

    Typographical conventions used in this document....................14 General conventions ............................14 General information............................15 SmartNode 4900 Series overview...........................16 SmartNode 4900 Series detailed description......................17 SmartNode 4900 Series front panel ........................18 SmartNode 4900 Series rear panels .........................19 Reset button behavior ..........................20 Applications overview............................ 21 Introduction ................................22 SmartNode 4900 Series applications........................22...
  • Page 5 ......................32 Grounding the Model SN4900—AC and DC units .................32 Installing the power cables—AC units .......................33 Installing the power cables—DC units ......................34 Getting started with the SmartNode 4900 Series................... 36 Introduction ................................37 1. Configure IP address ............................38 Factory-default IP settings ..........................38 Connect to the RS-232 console port .......................39...
  • Page 6 SmartNode 4900 Getting Started Guide Table of Contents Safety compliance: ............................52 PSTN Regulatory Compliance: ........................52 Radio and TV interference (FCC Part 15)......................52 CE Declaration of Conformity ..........................52 FCC Part 68 (ACTA) Statement (FXO ports).......................53 Industry Canada Notice (FXO Ports) ........................53 Specifications ..............................
  • Page 7 SmartNode 4900 Getting Started Guide Table of Contents 1. Definitions ..............................70 2. Title ................................70 3. Term ................................70 4. Grant of License ............................70 5. Warranty ..............................70 6. Termination ..............................71 7. Other licenses .............................71 Installation checklist ............................ 72 Introduction ................................73 Accessories ..............................74 Introduction ................................75...
  • Page 8: List Of Figures

    SmartNode 4900 rear panels ........
  • Page 9: List Of Tables

    List of Tables General conventions ..............14 Front panel LEDs .
  • Page 10: About This Guide

    About this guide This guide describes the SmartNode 4900 Series IpChannel Bank hardware, installation and basic configura- tion. For detailed software configuration information refer to the SmartWare Software Configuration Guide and the available Configuration Notes. Audience This guide is intended for the following users: •...
  • Page 11: Precautions

    SmartNode 4900 Series Getting Started Guide About this guide Precautions Notes, cautions, and warnings, which have the following meanings, are used throughout this guide to help you become aware of potential problems. Warnings are intended to prevent safety hazards that could result in per- sonal injury.
  • Page 12: Safety When Working With Electricity

    About this guide Safety when working with electricity The SmartNode contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service per- sonnel. Opening the SmartNode case will void the warranty. WARNING Mains Voltage: Do not open the case when either power cord is attached.
  • Page 13: Preventing Electrostatic Discharge Damage

    SmartNode 4900 Series Getting Started Guide About this guide Preventing Electrostatic Discharge Damage When starting to install interface cards place the interface card on its shielded plastic bag if you lay it on your bench. Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures.
  • Page 14: Typographical Conventions Used In This Document

    SmartNode 4900 Series Getting Started Guide About this guide Typographical conventions used in this document This section describes the typographical conventions and terms used in this guide. General conventions The procedures described in this manual use the following text conventions: Table 1.
  • Page 15: General Information

    Chapter 1 General information Chapter contents SmartNode 4900 Series overview...........................16 SmartNode 4900 Series detailed description......................17 SmartNode 4900 Series front panel ........................18 SmartNode 4900 Series rear panels .........................19 Reset button behavior ..........................20 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030...
  • Page 16: Smartnode 4900 Series Overview

    54 for a complete feature description of the SN4900 Series. The SmartNode 4900 Series comes equipped with two 10/100Base-T Ethernet ports, from 12 to 32 FXS ports, and an integrated optional V.35 or X.21 serial-WAN port. This provides voice-over-IP (VoIP) and Inter- net telephony integrated with routed serial-WAN access.
  • Page 17: Smartnode 4900 Series Detailed Description

    SmartNode 4900 Series detailed description The SmartNode 4900 Series IpChannel Bank provides VoIP calling from 12 to 32 analog phone lines. Inte- grated within the IpChannel Bank are 2 Ethernet ports, one for LAN, the other for WAN connectivity. The WAN service connection may also be made via either a serial V.35 or X.21 port.
  • Page 18: Smartnode 4900 Series Front Panel

    SmartNode 4900 Series Getting Started Guide 1 • General information SmartNode 4900 Series front panel The front panel LEDs display the status of the power, system, VOIP channels, Ethernet ports, and call load. The front panel includes the following LEDs.
  • Page 19: Smartnode 4900 Series Rear Panels

    SmartNode 4900 Series Getting Started Guide 1 • General information SmartNode 4900 Series rear panels The SmartNode 4900 rear panel ports are shown in figure 3 and described in table 3 on page 20. Model SN4932 0 -2 0 -6...
  • Page 20: Reset Button Behavior

    SmartNode 4900 Series Getting Started Guide 1 • General information Table 3. Port descriptions Port Description ETH 0/0 (WAN Ethernet 0/0 port) 10/100Base-Tx full-/half-duplex, RJ-45, auto detection and auto- MDI-X connects the unit to an Ethernet WAN device (for example, a cable modem, DSL modem, or fiber modem).
  • Page 21: Applications Overview

    Chapter 2 Applications overview Chapter contents Introduction ................................22 SmartNode 4900 Series applications........................22 Multiservice carrier access over leased lines ......................22 Enterprise FXS concentration and extension over IP and T1/E1 ..............23 Bulk analog line extensions ..........................23 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195...
  • Page 22: Introduction

    2 • Applications overview Introduction Patton's SmartNode 4900 Series deliver the features you need for advanced multiservice voice and data net- working. SmartNode 4900 Series combine high-quality voice-over-IP with powerful quality of service routing features to deliver seamlessly integrated VoIP and data access over synchronous serial leased lines. This chapter describes typical applications for which the SmartNode 4900 Series series is uniquely suited.
  • Page 23: Enterprise Fxs Concentration And Extension Over Ip And

    SmartNode 4900 Series Getting Started Guide 2 • Applications overview Like all members of the SmartNode family of VoIP solutions, the SmartNode 4900 Series supports all indus- try-standard VoIP signaling protocols, including SIP, H.323, T.38 fax-relay, plus fax- and modem-bypass. The...
  • Page 24: Hardware Installation

    Chapter 3 Hardware installation Chapter contents Introduction ................................26 Planning the installation ............................26 Installation checklist ............................27 Site log ................................27 Network information ............................28 Network diagram ............................28 IP related information ..........................28 Configuration tools ............................28 Power source ..............................28 Location and mounting requirements ......................29 Installing the IpChannel Bank..........................29 Unpacking the Model SN4900 series IpChannel Bank ...................29...
  • Page 25: Introduction

    SmartNode 4900 Series Getting Started Guide 3 • Hardware installation Introduction This chapter contains information for planning the installation of the SmartNode 4900 IpChannel Bank with the following installation procedures: • Section “Unpacking the Model SN4900 series IpChannel Bank” on page 28 lists the contents of the ship- ping box •...
  • Page 26: Installation Checklist

    5) lists the tasks for installing a SmartNode 4900 Series IpChannel Bank. Make a copy of this checklist and mark the entries as you complete each task. For each SmartNode 4900, include a copy of the completed checklist in your site log. This installation checklist is also available in appen- dix F, “Installation checklist”...
  • Page 27: Network Information

    Draw a network overview diagram that displays all neighboring IP nodes, connected elements and telephony components. IP related information Before you can set up the basic IP connectivity for your SmartNode 4900 series you should have the following information (see table •...
  • Page 28: Location And Mounting Requirements

    Location and mounting requirements The SmartNode 4900 is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables or be installed in a standard 19-inch rack chassis. Allow sufficient space at the rear of the chassis for cable connections.
  • Page 29: Connecting Cables

    SmartNode 4900 Series Getting Started Guide 3 • Hardware installation 6. Secure the IpChannel Bank in position with the mounting screws. 7. Go to section “Connecting cables” on page 29 Connecting cables This section describes installing the interface, power, and ground cables in the following order:...
  • Page 30: Connecting The Ethernet Ports

    SmartNode 4900 Series Getting Started Guide 3 • Hardware installation 3. Select and attach the appropriate twisted-pair from each FXS device on punch-down blocks for connection to the chosen port on the IpChannel Bank. Connecting the Ethernet ports The IpChannel Bank has dual 10/100 Ethernet interfaces. One is for the WAN connection. The other is for connecting to your Ethernet LAN.
  • Page 31: Connecting A 10/100Base-T Ethernet Port To An Ethernet-Capable Workstation

    Serial devices (V.35 or X.21) are connected to the SmartNode’s serial ports (see table 8) via a cable terminated at the SmartNode 4900. The V.35 connector is a DB-25 female and the X.21 uses a DB-15 female. The sync serial ports are configured as DTE. Table 8. Serial port pin-outs V.35 Interface (DB-25)
  • Page 32: Connecting To An External Power Source

    SmartNode 4900 Series Getting Started Guide 3 • Hardware installation Table 8. Serial port pin-outs V.35 Interface (DB-25) X.21 interface (DB-15) XTC-a (to DCE) Note Some NTUs have non-standard connections and require special cables. Consult the NTU maker’s product documentation Connecting to an external power source In connecting to the power source, it is important to establish a good grounding connection first, then the...
  • Page 33: Installing The Power Cables-Ac Units

    SmartNode 4900 Series Getting Started Guide 3 • Hardware installation Mains Voltage: Do not open the case when either power cord is attached. The SmartNode router is equipped with dual power supplies. Disconnect both power supply cords before servicing. For systems without a power switch,...
  • Page 34: Installing The Power Cables-Dc Units

    5. Connect the male end of the power cord to an appropriate power outlet. 6. Verify that the green POWER LED is lit. Hardware installation is complete. Refer to chapter 4, “Getting started with the SmartNode 4900 Series” page 36. Installing the power cables—DC units Mains Voltage: Do not open the case when either power cord is attached.
  • Page 35 The 36–72 VDC source is to be reliably connected to earth ground. 6. Verify that the green POWER LED is lit. Hardware installation is complete. Refer to chapter 4, “Getting started with the SmartNode 4900 Series” page 36. Installing the IpChannel Bank VoIPon www.voipon.co.uk...
  • Page 36: Getting Started With The Smartnode 4900 Series

    Chapter 4 Getting started with the SmartNode 4900 Series Chapter contents Introduction ................................38 1. Configure IP address ............................39 Factory-default IP settings ..........................39 Connect to the RS-232 console port .......................40 Login ................................41 Changing the WAN IP address ........................41 2. Connecting the SmartNode to the network .......................42...
  • Page 37: Introduction

    SmartNode 4900 Series Getting Started Guide 4 • Getting started with the SmartNode 4900 Series Introduction This chapter leads you through the basic steps to set up a new SmartNode and to download a configuration. Setting up a new SmartNode consists of the following main steps:...
  • Page 38: Configure Ip Address

    SmartNode 4900 Series Getting Started Guide 4 • Getting started with the SmartNode 4900 Series 3. Loading the configuration (see figure 16). Refer to section “2. Connecting the SmartNode to the net- work” on page 41 for details. 1. Download configuration example from the CD-ROM included with your SmartNode device or from the Patton Web server at www.patton.com/voip...
  • Page 39: Connect To The Rs-232 Console Port

    SmartNode 4900 Series Getting Started Guide 4 • Getting started with the SmartNode 4900 Series Note The SmartNode CD-ROM contains a collection of third party software tools (including TFTP servers and Telnet utilities) to help you configure, operate and monitor the SmartNode device.
  • Page 40: Login

    SmartNode 4900 Series Getting Started Guide 4 • Getting started with the SmartNode 4900 Series Login To access the SmartNode, start the Telnet application. Type the default IP address for the router into the address field: 192.168.1.1. Accessing your SmartNode via a Telnet session displays the login screen. Type the factory default login: administrator and leave the password empty.
  • Page 41: Connecting The Smartnode To The Network

    In general, the SmartNode will connect to the network via the ETH 0/0 (WAN) port. This enables the SmartNode to offer routing services to the PC hosts on the ETH 0/1 (LAN) port. The SmartNode 4900 Series is equipped with Auto-MDI-X Ethernet ports, so you can use straight-through or crossover cables for host or hub/switch connections (see figure...
  • Page 42: Bootloader

    ROM, it may have been added to the website. Note If your application is unique and not covered by any of Patton’s configura- tion templates, you can manually configure the SmartNode instead of load- ing a configuration file template. In that case, refer to the SmartNode Series SmartWare Software Configuration Guide for information on configuring the...
  • Page 43: Start-Up With Factory Configuration

    SmartNode 4900 Series Getting Started Guide 4 • Getting started with the SmartNode 4900 Series Start-up with factory configuration Step Command Purpose Copies the SmartWare application image from the RedBoot> fis load persistent memory (flash:) to the volatile memory (RAM) from where it will be executed.
  • Page 44 SmartNode 4900 Series Getting Started Guide 4 • Getting started with the SmartNode 4900 Series Step Command Purpose RedBoot> go Starts the application image that was down- loaded into the volatile memory (RAM). Note With the Bootloader, only the Ethernet interface 0/0 is available. The Boot- loader applies the IP address, subnet mask, and default gateway that were last configured by the Bootloader itself or by another application (e.g.
  • Page 45: Load A New Application Image (Smartware) Via The Serial Link

    For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the Software Configuration Guide on the enclosed CD-ROM or the Patton website at www.patton.com. On the CD you will also find a freeware TFTP server, which is also available from the www.solarwinds.net web site.
  • Page 46: Leds Status And Monitoring

    Chapter 5 LEDs status and monitoring Chapter contents Status LEDs................................43 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030...
  • Page 47: Status Leds

    SmartNode 4900 Series Getting Started Guide 5 • LEDs status and monitoring Status LEDs The front panel LEDs display the status of the power, system, VoIP channels, Ethernet ports, and call load. They are described in table 10. Rear panel serial port LEDs are described in table Table 10.
  • Page 48: Contacting Patton For Assistance

    Chapter 6 Contacting Patton for assistance Chapter contents Introduction ................................45 Contact information..............................45 Warranty Service and Returned Merchandise Authorizations (RMAs)..............45 Warranty coverage ............................45 Out-of-warranty service ..........................46 Returns for credit ............................46 Return for credit policy ..........................46 RMA numbers ..............................46 Shipping instructions ..........................46 VoIPon www.voipon.co.uk...
  • Page 49: Introduction

    SmartNode warranty and obtaining a return merchandise authorization (RMA). Contact information Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we...
  • Page 50: Out-Of-Warranty Service

    RMA#: xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs. Warranty Service and Returned Merchandise Authorizations (RMAs) VoIPon www.voipon.co.uk...
  • Page 51 Appendix A Compliance information Chapter contents Compliance ................................53 EMC compliance: ............................53 Safety compliance: ............................53 PSTN Regulatory Compliance: ........................53 Radio and TV interference (FCC Part 15)......................53 CE Declaration of Conformity ..........................53 FCC Part 68 (ACTA) Statement (FXO ports).......................54 Industry Canada Notice (FXO Ports) ........................54 VoIPon www.voipon.co.uk...
  • Page 52: A Compliance Information

    SmartNode 4900 Series Getting Started Guide A • Compliance information Compliance EMC compliance: • FCC Part 15, Class A • EN55022, Class A • EN55024 Safety compliance: • UL60950-1/CSA C22.2 No. 60950-1 • IEC/EN 60950-1 • AS/NZS 60950-1 PSTN Regulatory Compliance: •...
  • Page 53: Fcc Part 68 (Acta) Statement (Fxo Ports)

    SmartNode 4900 Series Getting Started Guide A • Compliance information FCC Part 68 (ACTA) Statement (FXO ports) This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX.
  • Page 54 Appendix B Specifications Chapter contents Voice connectivity - FXS ............................55 Voice connectivity - FXO ............................55 Ethernet interface ..............................55 Console port................................55 Serial ports................................55 FXS ports ................................56 FXO ports ................................56 PPP and Frame-Relay support ..........................56 Voice processing (signaling dependent)........................56 Fax and modem support............................56 Voice signaling ..............................57...
  • Page 55: B Specifications

    SmartNode 4900 Getting Started Guide B • Specifications Voice connectivity - FXS 2-wire Loopstart, RJ-11/12 Short haul loop 1.1 km @3REN EuroPOTS (ETSI EG201 188) Programmable AC impedance, feeding, and ring voltage; on-hook voltage 48 VDC Caller-ID Type-1/2 FSK and ITU V.23/Bell 202 generation...
  • Page 56: Fxs Ports

    SmartNode 4900 Getting Started Guide B • Specifications FXS ports The FXS ports provide for connection of up to 32 analog FXS devices on a 50- or 64-pin RJ-21X connector located on the rear panel. FXO ports The FXO ports provide for connection of up to 32 analog FXO devices on a 50- or 64-pin RJ-21X connector located on the rear panel.
  • Page 57: Voice Signaling

    SmartNode 4900 Getting Started Guide B • Specifications Fax over IP (FoIP) T.38 Fax relay (9.6 k, 14.4 k) Voice signaling H.323v4: • RAS, H.225, H.245 • Fast-connect, early H.245 • Gatekeeper autodiscovery • Alias registration • Overlap sending •...
  • Page 58: Management

    SmartNode 4900 Getting Started Guide B • Specifications 802.1p VLAN tagging IPSEC AH & ESP Modes Manual Key; IKE optional AES/DES/3DES Encryption Management Industry standard CLI with local console (RJ-45, RS-232) and remote Telnet access TFTP configuration & firmware loading...
  • Page 59: Power Supply

    SmartNode 4900 Getting Started Guide B • Specifications Table 12. SmartNode weight and maximum power specifications SmartNode model Weight Maximum power dissipation IpChannel Bank 4932 9.1 lb (4.1 kg) V.35 or X.21 Serial Card (Expansion Port) 0.1 lb (45.3 g)
  • Page 60 Appendix C Port pin-outs Chapter contents Introduction ................................61 Console port................................61 Ethernet 10Base-T and 100Base-T port.........................61 Sync Serial port ..............................62 FXS and FXO ports...............................63 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030...
  • Page 61: C Port Pin-Outs

    SmartNode 4900 Series Getting Started Guide C • Port pin-outs Introduction This section provides pin-out information for the ports of the SmartNode. Console port Configuration settings: Asynchronous data rate of 9600 bps, 2 bits, no parity, 1 stop bit, no flow control...
  • Page 62: Sync Serial Port

    SmartNode 4900 Series Getting Started Guide C • Port pin-outs Sync Serial port Two types of serial ports are available: V.35 or X.21. They are configured as DTE. The V.35 is presented on a DB-25 female connector (see table 14 for pin-outs).
  • Page 63: Fxs And Fxo Ports

    SmartNode 4900 Series Getting Started Guide C • Port pin-outs FXS and FXO ports The FXS and FXO ports are accessed through a 64-pin RJ-21X connector (see table 16 for pin-outs) or through a 50-pin RJ-21X connector (see table 17 on page 65 for pin-outs) located on the rear panel of the IpChannel Bank.
  • Page 64 SmartNode 4900 Series Getting Started Guide C • Port pin-outs Table 16. Band marked color-codes for the 64-pin RJ-21X connector (Continued) Wire/Color Code 64 Pin Binder Color Tip & Ring Pair Number Positions Main color Stripe Tip 17 Yellow Blue...
  • Page 65: Band Marked Color-Codes For The 50-Pin Rj-21X Connector

    SmartNode 4900 Series Getting Started Guide C • Port pin-outs Table 17. Band marked color-codes for the 50-pin RJ-21X connector Wire/Color Code 50 Pin Tip & Ring Pair Number Positions Main color Stripe Tip 1 White Blue Pair 1 Ring 1...
  • Page 66 SmartNode 4900 Series Getting Started Guide C • Port pin-outs Table 17. Band marked color-codes for the 50-pin RJ-21X connector (Continued) Wire/Color Code 50 Pin Tip & Ring Pair Number Positions Main color Stripe Tip 19 Yellow Brown Pair 19...
  • Page 67: Factory Configuration

    Appendix D Factory Configuration Chapter contents Introduction ................................62 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030...
  • Page 68: Introduction

    SmartNode 4900 Getting Started Guide D • Factory Configuration Introduction The factory configuration settings for SmartNode 4900 Series devices are as follows: #----------------------------------------------------------------# # 4900 Series # Factory configuration file #----------------------------------------------------------------# dns-relay sntp-client sntp-client server primary 129.132.2.21 port 123 version 4...
  • Page 69: E End User License Agreement

    Appendix E End user license agreement Chapter contents End User License Agreement ..........................64 1. Definitions ..............................64 2. Title ................................64 3. Term ................................64 4. Grant of License ............................64 5. Warranty ..............................64 6. Termination ..............................65 7. Other licenses .............................65 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030...
  • Page 70: End User License Agreement

    Program(s), even if Patton Electronics Company has been advised of the possibil- ity of such damages. Because some states do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.
  • Page 71: Termination

    The End User may terminate this agreement by returning the Designated Equipment and destroying all copies of the licensed Program(s). Patton Electronics Company may terminate this Agreement should End User violate any of the provi- sions of section “4. Grant of License”...
  • Page 72: Installation Checklist

    Appendix F Installation checklist Chapter contents Introduction ................................67 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030...
  • Page 73: Introduction

    SmartNode 4900 Getting Started Guide F • Installation checklist Introduction This appendix lists the tasks for installing a SmartNode 4900 IpChannel Bank (see table 18). Make a copy of this checklist and mark the entries as you complete each task. For each IpChannel Bank, include a copy of the completed checklist in your site log.
  • Page 74: Accessories

    Appendix G Accessories Chapter contents Introduction ................................69 VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030...
  • Page 75: Introduction

    SmartNode 4900 Getting Started Guide G • Accessories Introduction The cables listed in table 19 are available as accessories for the SmartNode 4900 Series products. Table 19. Accessory cables Description Part Number DB-25 male to M/34 male cable (Sync serial V.35 port) 1205-25M/35M DB-15 male to DB-15 male cable (Sync serial X.21 port)