Time Offset; Units Setup; Nmea Out On/Off; Auxiliary Alarm Select - Raymarine ST60+ Owner's Handbook Manual

Graphic display
Hide thumbs Also See for ST60+:
Table of Contents

Advertisement

Chapter 4: Calibration
41

Time offset

Use the track or reset button to apply an appropriate offset to set your system
time to local time. You can set any offset in the range -12 hours to +12 hours, in
half-hour increments. The time with the offset applied is shown at the bottom of
the screen.

Units setup

The units in which SeaTalk data is displayed, are determined by the respective
master instruments. However, as the ST60+ Graphic Display can also display
NMEA data, the Units setup screen enables you to set the units for this data.
Setting units
With the Units setup screen displayed, use the
button to move to each data
type in turn and for each, use the
or
button to select the required unit.
track
reset

NMEA OUT on/off

The NMEA OUT on/off screen enables you to set which function the NMEA
OUT
connector provides. This is either:
• NMEA data out.
or
• Alarm signals for the Auxiliary Alarm.
If want to output NMEA data, use the track or reset button to select NMEA
OUT ON . If you want to output alarm signals to the Auxiliary Alarm, select
NMEA OUT OFF .

Auxiliary Alarm select

Use the ALARM DRIVE screen to determine which alarms you want to sound
at the Auxiliary Alarm.
The NMEA OUT function must be OFF , to enable the Auxiliary Alarm to be used.
Note:
Use the track or reset button to set ALARM DRIVE OFF , if you do not want
any alarms to sound at the Auxiliary Alarm. Otherwise, set ALARM DRIVE ON
If you have set ALARM DRIVE ON , use the
button to move to each alarm
in turn and for each, use the
or
button to either enable ( ) or disable
track
reset
( ) the alarm.

Pilot pop-up

Use the track or reset button to set the PILOT POPUP either ON or
OFF , as required.