2.2 Chuck
TE‑Y (SDS-max) quick-change "click" chuck (TE 60 / TE 60‑ATC)
2.3 Switches
Speed-control switch for smooth hole-starting / chiseling
Function selector switch: Hammer drilling, chiseling, chisel adjustment (24 positions)
Power selector switch for full or reduced (50%) power (ATC)
Control switch lockable for chiseling
2.4 Grips
Vibration-absorbing, pivotable side handle
Vibration-absorbing grip (ATC)
2.5 Protective devices
Mechanical safety clutch
Electronic restart interlock to prevent the power tool starting unintentionally after an interruption in the electric supply
(see section "Troubleshooting").
ATC Active Torque Control (TE 60‑ATC)
2.6 Lubrication
Gearing and hammering mechanism with separate lubrication chambers
2.7 Active Vibration Reduction (ATC)
The power tool is equipped with an AVR Active Vibration Reduction system which reduces vibration significantly
compared to power tools without AVR.
2.8 TPS theft protection system (ATC)
The power tool may be equipped with the TPS Theft Protection System as an option. If the power tool is equipped
with this feature, it can be unlocked and made ready for operation only through use of the corresponding TPS key.
2.9 LED indicators
Service indicator LED (see section "Care and maintenance / service indicator")
Theft protection system indicator (ATC) (see section "Operation / TPS theft protection system (optional)")
Reduced (50%) power indicator (see section "Operation / hammer drilling / chiseling")
2.10 Items supplied as standard
1
Power tool with side handle
1
Grease
1
Cleaning cloth
1
Operating instructions
1
Hilti toolbox
2.11 Using extension cords
Use only extension cords of a type approved for the application and with conductors of adequate cross section.
The power tool may otherwise lose performance and the extension cord may overheat. Check the extension cord for
damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths
Conductor cross section
Mains voltage 100 V
Mains voltage 110-127 V
Mains voltage 220-240 V
Do not use extension cords with 1.25 mm² conductor cross section.
1.5 mm²
2.0 mm²
20 m
20 m
25 m
30 m
2.5 mm²
3.5 mm²
40 m
30 m
40 m
50 m