Flue Options - Worcester 29CDi GC 47-406-34 Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing combination boiler
Table of Contents

Advertisement

PRE-INSTALLATION
3.8

FLUE OPTIONS

The Greenstar CDi has the option of three horizontal RSF (60/100
telescopic, 60/100 longer telescopic and 80/125 telescopic) flue
system and two vertical RSF (60/100 or 80/125) regular flue systems:
The systems have different maximum flue lengths
Maximum horizontal flue lengths (L)
Boiler model
100mmØ
29CDi
7,000mm
34CDi
7,000mm
38CDi
6,500mm
42CDi
6,000mm
Maximum vertical flue lengths (L)
Boiler model
100mmØ
29CDi
8,000mm
34CDi
8,000mm
38CDi
8,000mm
42CDi
7,500mm
This page and the next page show various flue options with the maximum
straight flue lengths required to achieve the maximum flue length.
NOTICE: 60/100 Flue systems:
B Each 90° bend used is equivalent to 1.5 metres of
straight flue.
B Each 45° bend used is equivalent to 0.75 metres of
straight flue.
NOTICE: 80/125 flue systems:
B Each 90° bend used is equivalent to 2 metres of
straight flue.
B Each 45° bend used is equivalent to 1 metre of
straight flue.
Telescopic horizontal flue
Flue option 1
100mmØ
29CDi
570mm
34CDi
570mm
38CDi
570mm
42CDi
570mm
Horizontal extended flue
Flue option 2
100mmØ
29CDi
7,000mm
34CDi
7,000mm
38CDi
6,500mm
42CDi
6,000mm
Horizontal extended flue with 1x90° bends
Flue option 3
100mmØ
29CDi
5,500mm
34CDi
5,500mm
38CDi
5,000mm
42CDi
4,500mm
16
Horizontal extended flue with 2x90° bends
Flue option 4
29CDi
34CDi
38CDi
125mmØ
42CDi
16,000mm
16,000mm
High level horizontal extended flue
17,200mm
Flue option 5
12,500mm
29CDi
34CDi
38CDi
125mmØ
42CDi
16,000mm
16,000mm
High level horiz. extended flue with 2x90° bends
18,400mm
Flue option 6
16,000mm
29CDi
34CDi
38CDi
42CDi
High level horiz. extended flue with 3x90° bends
Flue option 7
29CDi
34CDi
38CDi
42CDi
Vertical balanced flue assembly
Flue option 8
29CDi
34CDi
38CDi
125mmØ
42CDi
600mm
Vertical balanced flue with 2x90° bends
600mm
Flue option 9
600mm
29CDi
600mm
34CDi
38CDi
125mmØ
42CDi
16,000mm
Vertical balanced flue system with 2x45° bends
16,000mm
Flue option 10
17,200mm
29CDi
12,500mm
34CDi
38CDi
125mmØ
42CDi
14,000mm
14,000mm
15,200mm
10,500mm
100mmØ
125mmØ
4,000mm
12,000mm
4,000mm
12,000mm
3,500mm
13,200mm
3,000mm
8,500mm
100mmØ
125mmØ
7,000mm
16,000mm
7,000mm
16,000mm
6,500mm
17,200mm
6,000mm
12,500mm
100mmØ
125mmØ
4,000mm
12,000mm
4,000mm
12,000mm
3,500mm
13,200mm
3,000mm
8,500mm
100mmØ
125mmØ
2,500mm
10,000mm
2,500mm
10,000mm
2,000mm
11,200mm
1,500mm
6,500mm
100mmØ
125mmØ
8,000mm
16,000mm
8,000mm
16,000mm
8,000mm
18,400mm
7,500mm
16,000mm
100mmØ
125mmØ
5,000mm
12,000mm
5,000mm
12,000mm
5,000mm
14,400mm
4,500mm
12,000mm
100mmØ
125mmØ
6,500mm
14,000mm
6,500mm
14,000mm
6,500mm
16,400mm
6,000mm
14,000mm
6 720 803 599 (2012/06)