SERVICING AND SPARES
6.1.2 FAN PRESSURE TEST
This test is to determine if the heat cell requires cleaning/
attention
SET THE BOILER TO MAXIMUM
B When running in the Performance test mode, the
boiler will operate only the Central Heating circuit.
B The heating output can be limited to any level between
minimum and maximum rated heat output to suit a
specific requirement.
Even when the heat output is limited, full heat output
is still available for domestic hot water.
B
A
L
K
3
4
5
2
J
1
6
max
I
Fig. 47 Control panel
[A]
ON/OFF button
[B]
Cover or optional plug-in controller
[C]
Display
[D]
System pressure gauge
[E]
Reset button
[F]
ECO button
[G]
Holiday button
[H]
DHW temperature control
[I]
Central heating control
[J]
Performance test button
[K]
Service button
[L]
Burner indicator (green)
[M]
ON/OFF and fault indicator (blue)
B Press and HOLD the Performance test button (J) for 10 seconds and
set Central Heating temperature to maximum.
– The Performance test button will illuminate continually.
– The boiler will stay in this mode for 15 minutes unless the
Performance test button is pressed again.
B Pull the cover off and connect a manometer to the fan pressure test
point.
B After measurement replace test point cover.
36
C
2
1
1
3
0
4
bar
D
reset
eco
E
F
3
4
e
2
G
1
6
min
max
H
M
6720647361-23.2Wo
FAN PRESSURE TEST
Clean the Heat Ex.
NG Boilers
42 CDi:
38 CDi:
34 CDi:
29 CDi:
0
-1
-2
-3
LPG Boilers
42 CDi:
38 CDi:
34 CDi:
29 CDi:
0
-1
-2
-3
Fig. 48 Fan pressure readings
• Pressures readings in the black area will indicate that the heat
exchanger requires attention/cleaning.
• There is a special accessory kit available specifically designed for
cleaning the heat exchanger.
Part number 7 719 001 996.
Fig. 49 Fan pressure test point
Heat Ex. ok
- 4.8
- 4.4
- 5.3
- 3.9
-4
-5
-6
-7
-8
mbar
- 4.8
- 4.4
- 5.3
- 3.9
-4
-5
-6
-7
-8
mbar
3.
6720647361-28.1Wo