Worcester 29CDi GC 47-406-34 Installation, Commissioning And Servicing Instructions page 47

Wall hung rsf gas fired condensing combination boiler
Table of Contents

Advertisement

27. CH PRESSURE RELIEF VALVE
B Remove the Hydraulic block from the boiler (See Removing the
Hydraulic Block).
1. Remove the spring clip from the Pressure relief valve housing.
2. Withdraw the pressure release valve (A) from its housing.
B To refit, follow the above in reverse.
B Ensure any seals that have been disturbed are renewed.
Fig. 78 Pressure relief valve removal
28. PLASTIC PROTECTION DEVICE
B Ensure the system is fully drained.
B Disconnect all pipes connected to the pump housing.
B Remove the electrical connection to the pump.
B Withdraw the metal clip to the right of the pump head to release the
pump housing.
B Slide the device to the left and then withdraw it from the appliance.
1. Remove the spring clip from the pressure relief valve housing.
6 720 803 599 (2012/06)
27.1
27.2
A
6720647361-45.1Wo
2. Withdraw the pressure relief valve (A). To refit, follow the above in
reverse.
B Ensure any seals that have been disturbed are renewed.
Fig. 79 Plastic protection device removal
29. DHW HEAT EXCHANGER
B Remove the Hydraulic block from the boiler (See Removing the
Hydraulic Block).
B Undo the two screws (B) securing the plastic housings to the heat
exchanger.
B Remove the heat exchanger.
B To refit, follow the above in reverse.
B Ensure any seals that have been disturbed are renewed.
B
Fig. 80 DHW Heat Exchanger removal
SERVICING AND SPARES
28.1
28.2
A
6720647361-46.1Wo
6720647361-47.2Wo
47