Display Protection; External Control - NEC E705 User Manual

Lcd monitor
Hide thumbs Also See for E705:
Table of Contents

Advertisement

DISPLAY PROTECTION

POWER SAVE
Sets how long the monitor waits to go into power save mode after the signal is lost.
NOTE: When connecting DVI, the video card might not stop sending the digital data even
though the image might have disappeared. If this occurs the monitor will not switch into power
management mode.
AUTO POWER SAVE
The monitor automatically goes into OFF at the preset time period after signal is lost.
The monitor will return to normal mode when signal is restarted.
AUTO STANDBY
The monitor automatically goes into OFF at the preset time period after signal is lost.
Press the power button to return to normal mode.
DISABLE
The monitor will not goes into OFF after signal is lost.
HEAT STATUS
Displays status of the FAN, BACKLIGHT and TEMPERATURE.
FAN CONTROL
Cooling fan reduces the temperature of the display to protect from overheating.
If "AUTO" is selected, you can adjust the start temperature of the cooling fan and fan speed.
SCREEN SAVER
Use the SCREEN SAVER function to reduce the risk of Image Persistence.
GAMMA
The display gamma is changed and fixed when "ON" is selected.
BACKLIGHT
The brightness of backlight is decreased when "ON" is selected.
NOTE: Do not select this function when ROOM LIGHT SENSING is MODE1 or MODE2.
MOTION
The screen image is slightly expanded and moves in 4 directions (UP, DOWN, RIGHT, LEFT) at
user determined intervals. You can set interval time and zooming ratio.
This function is disabled when PIP, STILL, TEXT TICKER are enabled.
SIDE BORDER COLOR
Adjusts the color of the side borders when a 4:3 image is displayed.
Press + button, the bar will become lighter.
Press - button, the bar will become darker.
CHANGE PASSWORD
Allows the security password to be changed.
The factory preset password is 0000.
SECURITY
Locks the security password.
START-UP LOCK: Security password is required when the monitor power is on.
CONTROL LOCK: Security password is required when the remote control button or control button
on the monitor is pressed.
BOTH LOCK: Security password is required when the monitor power is on, or the remote control
button or control button on the monitor is pressed.
RESET
Resets the following settings within the DISPLAY PROTECTION menu back to factory setting:
POWER SAVE, FAN CONTROL, SCREEN SAVER, SIDE BORDER COLOR.

EXTERNAL CONTROL

IP ADDRESS SETTING
NOTE: When changing the LAN SETTING, you need to wait several seconds until the LAN
SETTING is applied.
IP SETTING
Enabling this option automatically assigns an IP address to the monitor from your DHCP server.
Disabling this option allows you to register the IP address or subnet mask number obtained from
your network administrator.
NOTE: Consult your network administrator for the IP address when "AUTO" is selected for
[IP SETTING].
IP ADDRESS:
Set your IP address of the network connected to the monitor when "MANUAL" is selected for
[IP SETTING].
English-25
AUTO
STANDBY
-
-
-
-
AUTO, HIGH
OFF
OFF
OFF
15
-
OFF
-
AUTO
192.168.0.10