7-2. MIG Welding Mode - GMAW/FCAW Process

!
Weld
terminals
are
through the remote control in MIG
welding mode.
1
Mode Switch
2
Volts Indicator
3
Left Display
4
Right Display
5
Adjust Control
6
Wire Type Indicator
7
Arc Control Indicator
8
Setup Button
9
Gas Type Indicator
Setup
For typical system connections refer to
Section 7-1.
Rotate Mode Switch to MIG position as
shown.
The preset voltage is shown in the Left Dis-
play with the Volts Indicator lit.
Operation
While the Volts Indicator is lit under the Left
Display, the Adjust Control is used to set
desired preset voltage.
2
3
2
5.0
.
energized
The preset voltage can be adjusted re-
motely at the wire feeder if the feeder
has a voltage control. This voltage con-
trol will override the Adjust Control of
preset voltage on the welding power
source.
Pressing the Setup Button allows adjust-
ment of Arc Control, Wire Type, Gas Type
and preset voltage.
.
For best results, select the appropriate
Wire and Gas Type to match the actual
wire and gas being used. Refer to the
MIG − Wire and Gas Selection Table
for available wires and gases (see
Section 7-3).
Selecting a Wire and Gas
Press the Setup Button repeatedly until the
Wire Type indicator is lit. The active Wire
Type will appear in the Left and Right Dis-
play.
Rotate Adjust Control to select desired
wire.
Press the Setup Button again so the Gas
Type indicator is lit. The active Gas Type
will appear in the Left and Right Display.
Rotate Adjust Control to select desired gas.
4
5
1
Press the Setup Button to confirm the
selection. The unit will acknowledge a
change of wire and gas information by dis-
playing PROG LOAD momentarily.
Arc Control (Inductance)
Press the Setup Button repeatedly until the
Arc Control indicator is lit. INDU appears on
the Left Display, and the corresponding in-
ductance setting appears on the Right Dis-
play.
Rotate Adjust Control to select desired in-
ductance setting from 0 to 100. Use lower
inductance settings to stiffen the arc and re-
duce puddle fluidity. Use higher inductance
settings to soften the arc and increase
puddle fluidity.
Refer to the MIG − Wire and Gas Selection
Table (see Section 7-3) for suggested in-
ductance setting for the specific wire and
gas being used.
Press the Setup Button to return to adjust-
ment of preset voltage.
.
Each Wire and Gas Type combination
has independent preset voltage and in-
ductance settings. These settings are
preserved when the unit is turned off.
6
7
8
9
226 611-A
OM-237 881 Page 29