Remote 14 Receptacle Information; Optional 115 Volts Ac Duplex Receptacle And Supplementary Protectors - Red-D-Arc EXTREME 360 MAP Auto-Line Owner's Manual

Table of Contents

Advertisement

4-5. Remote 14 Receptacle Information

A
J
K
I
B
C L N
H
M
D
G
F
E
*The remaining sockets are not used.

4-6. Optional 115 Volts AC Duplex Receptacle And Supplementary Protectors

24 VOLTS AC
115 VOLTS AC
REMOTE
OUTPUT
CONTROL
A/V
AMPERAGE
VOLTAGE
GND
1
Socket*
Socket Information
A
24 volts AC. Protected by supplementary protect-
or CB2.
B
Contact closure to A completes 24 volts AC
contactor control circuit.
I
115 volts AC. Protected by supplementary pro-
tector CB1.
J
Contact closure to I completes 115 volts AC
contactor control circuit.
C
Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
L
Wirefeed speed command, 0 to +10 volts DC out-
put signal from wire feeder.
M
CC/CV Select; 0 to +10 volts DC.
N
Wirefeed speed common.
F
Current feedback; +1 volt DC per 100 amperes.
H
Voltage feedback; +1 volt DC per 10 output recep-
tacle volts.
G
Circuit common for 24 and 115 volts AC circuits.
K
Chassis common.
1
115 V 10 Amp AC Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 4-5).
2
Supplementary Protector CB1
3
Supplementary Protector CB2
CB1 protects duplex receptacle
and 115 volts AC portion of Remote
14 receptacle from overload.
CB2 protects 24 volts AC portion of
Remote
overload.
Press button to supplementary pro-
tector.
2
3
14
receptacle
from
803 691-C
OM-237 881 Page 15

Advertisement

Table of Contents
loading

Table of Contents