Chapter 4: User Maintenance; Cleaning; Dust Removal; Error Codes - Outline TFive User Manual

2 channel power amplifier
Table of Contents

Advertisement

Professional amplifiers
4 User maintenance

4.1 Cleaning

Disconnect the amplifier from the AC main source first; use a soft cloth and mild non-abrasive solution to clean the
faceplate and chassis.

4.2 Dust removal

Especially in a dusty environment, the front side filters clog with dust after prolonged use, this will interfere with cooling.
You may use compressed air to remove the dust from filters. To remove air filters see fig(3.4.1) , unscrew n° 2 M2,5X8
screw and rotate the covering grill; repeat the same operation on the other side.
coverage

4.3 Error Codes

Error code
Error descr.
192KHz clock not present
1
Positive 15V aux
2
4
Negative 15V aux
8
Positive 5V analog
100
Negative power bus Ch1
200
Negative power bus Ch2
2000
Positive power bus Ch1
4000
Positive power bus Ch2
8000
External auxiliary voltage
Check rail fuses Ch1 and Ch2
Check rail fuses

4.4 Service

There are no user-serviceable parts in your amplifier. Refer servicing to qualified technical personnel.
In addition to having an in-house service department, Outline supports a network of authorized service centers. If your
amplifier needs repair, contact your Outline dealer or distributor, or contact the Outline Technical Service department, to
obtain the location of the nearest authorized service center.
Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it E-Mail: info@outline.it
grill
screw
filter
Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy
figure 4.3.1
The error code value displayed in the main screen is
the sum of the single error code value.
Example: 4301=4000+200+100+1
Positive power bus Ch2
Negative power bus Ch2
Negative power bus Ch1