CONFORMITY WITH CLEAN ANY PART OF THE AMPLIFIER DIRECTIVE 2012/19/EC CLASS3 WIRING OUTLINE SUGGESTS TO PLUG THE TTM TO A 16 A RATING, C OR D EUROPEAN PARLIAMENT ON WASTE CURVE, 10 kA SECTIONING BREAKER. ELECTRICAL ELECTRONIC CLASS3 EQUIPMENT (WEEE).
Page 5
The wide blade or the third prong are provided for your safety. If OUTLINE S.R.L. Tel.: +39 030.3581341 www.outline.it Via Leonardo da Vinci, 56 Fax +39 030.3580431...
Outline s.r.l. comply with the Directive accordance with the instruction manual, may cause 2012/19/EU of the European Parliament on waste harmful interference to radio communications.
The following harmonized standards are applied: EN 55032:2012, EN 55032:2012/AC:2013 EN 55035:2017 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 61000-3-11:2000 EN 62368-1:2014 EN 62368-1:2014/AC:2015 Flero, May 2022 OUTLINE S.R.L. Tel.: +39 030.3581341 www.outline.it Via Leonardo da Vinci, 56 Fax +39 030.3580431 25020 Flero (Brescia) Italy info@outline.it...
The TTM Series amplifiers can be stacked one on top of the other, but it is recommended to leave one rack unit empty every three amplifiers to guarantee adequate air flow.
AC MAINS SUPPLY The TTM Series amplifiers implement a universal AC mains connection can be found in the rear panel switching mode power supply, with power factor through the IEC C20 inlet. The approved power cord correction operating in the range from 100 VAC up to is provided.
(1), a rotary encoder with pushbutton (3), a power status LED (4), and a ‘Back/ArmoníaPlus Callback pushbutton (5). Users can select what parameters to control and navigate through the OUTLINE TTM 8K4 HOME different display options and pages available, by - VEGAS 12 CX >60 dB...
ArmoníaPlus or the screen panel (see ‘Net Config’ section). server before connecting the amplifiers. If a DHCP server is not active in the network, the OUTLINE S.R.L. Tel.: +39 030.3581341 www.outline.it Via Leonardo da Vinci, 56 Fax +39 030.3580431 25020 Flero (Brescia) Italy info@outline.it...
ARMONIAPLUS SYSTEM DESIGN ArmoníaPlus System Manager is the default and the TTM Series must belong to the same subnet. interface that allows setting and customisation of the Download ArmoníaPlus System Manager for free TTM Series amplifiers. Note that whenever the TTM from the website: is connected to ArmoníaPlus, the front panel display...
AES3 Link Out 1-2 (1GND/2+/3-) AES3 Link Out 3-4 (1GND/2+/3-) Network Connectors AC Mains Connector ETH 1 (RJ45) ETH 2 (RJ45) IEC C19 OUTLINE S.R.L. Tel.: +39 030.3581341 www.outline.it Via Leonardo da Vinci, 56 Fax +39 030.3580431 25020 Flero (Brescia) Italy info@outline.it...
NOTES OUTLINE S.R.L. Tel.: +39 030.3581341 www.outline.it Via Leonardo da Vinci, 56 Fax +39 030.3580431 25020 Flero (Brescia) Italy info@outline.it...
Page 16
For this reason, any current Outline product may differ in some aspect from its description, but will always equal or exceed the original design specifications unless otherwise stated.