Setting Procedure - Chamberlain Elite EL Series Programming Manual

Telephone entry/access control system
Hide thumbs Also See for Elite EL Series:
Table of Contents

Advertisement

Q u i c k R e f e r e n c e
Programming
Page
Number
57
34
Delete an Entry Code
58
37
Assign Utility Option
59
37
Assign Special Use Entry Code
60
24
Assign Each External Access Control
Device a "Door Number"
61
24
Assign "Each" Door Number to One or
More Relays
63
51
Assign Door Use Time Zone
64
53
Set Anti-Passback Entry/Exit for
Specific Devices
65
23
Set Each "Relay Mode" to get the
Appropriate Response
66
23
Set Each Relay's "Activation Time"
67
65
Request to Exit Device (REX)
68
66
Door Sensing Devices
69
64
Postal Lock Switch
70
64
Autocall Device
71
43
Set the Default Card Type
73
43
Set the Default Facility Code
74
43
Enable or Disable Ignore Facility Code
when a Card is Used
75
36
Change Entry Code Door Access
78
40
Change Card Code Door Access
80
40
Add a Basic Card
81
41
Add or Edit a Full Function Card
82
41
Add a Group of Cards at Once
Factory
Description of Task
Setting
Main keypad
assigned door1
Device 1=door 1
Device 2=door 2
Device 3=door 3
Device 4=door 4
D1=Relay 1
D2=Relay 2
D3=Relay 3
D4=Relay 4
Enabled
Disabled
All Relays=
"1-Strike"
All Relays=
10 seconds
R1=Door 1
R2=Door 2
R3=Door 3
R4=Door 4
DS1= Door 1
DS2= Door 2
DS3= Door 3
DS4= Door 4
Door 1
Enabled
All Doors
All Doors
Page 6
Programming
Procedure
57 # (entry code) #
Off
58 # (entry code) # (Option; 0=Off, 1=Daily,
2=Weekly, 3=Never) # (number of uses 1-15)
59 # (entry code) # enable/disable #
60 # (device 1-4) # (door 1-4) #
61 # (door 1-4) # (relays to activate 0000-1111) # Order
of relay is: relay 4-relay -3 -relay 2-relay 1 for an
example if you want relay 4 active you would enter
1000, if if you want relay 1 active you would enter 0001
63 # (door 1-4) # (time zone, 0-63) #
64 # (device 0-4) # (0-3; 0=disable, 1=set device
to timed anti-passback, 2=set device to true anti-
passback-entrance, 3=set device for true anti-
passback-exit) #
65 # (relay 1-4) # (1-5; 1=strike, 2=shunt, 3=CCTV,
4=alarm, 5=control) #
66 # (relay 1-4) # time (1-300 seconds)
67 # (REX number 1-4) # (select REX option:
0=disabled, 1=use your door settings or 2=use specific
relay(s) 0000-1111) #
Order of Relays are 4321
68 # (sensor number 1-4) # (select sensor option:
0=disabled, 1=use your door settings or 2=use specific
relay(s) 0000-1111) #
Order of Relays are 4321
69 # (door 0-4; 0=no postal lock) #
0000
70 # (relays to activate 0000-1111) #
Order of relays are 4321 (Factory Default: 0000)
30
71 # (26 or 30) # (Factory Default: 30)
0
73 # (0-255) #
74 # (0=disable; 1=ignore) #
75 # (entry code) # (door 0=any door, 1=door 1,
2=door 2, 3=door 3, 4=door 4) #
78 # (card code) # (facility code) # (card type,
26 or 30) # (door 0=any door, 1=door 1,
2=door 2, 3=door 3, 4=door 4) #
80 (card PIN code) # (facility code) # (card type,
26 or 30) #
81 # (card PIN code) # (facility code) (card type, 26 or
30) # (schedule for door 1, 0-63) # (schedule for door
2, 0-63) # (schedule for door 3, 0-63) # (schedule for
door 4, 0-63) #
82 # (card PIN code start range) # (card PIN code end range)
# (facility code) # (card type, 26 or 30) # (0=deactivate,
1=activate) # (schedule for door 1, 0-63) # (schedule for
door 2, 0-63) # (schedule for door 3, 0-63) # (schedule for
door 4, 0-63) # name (0-20 characters) #

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents