Kingsman FDV200 Installation Instructions Manual

Free standing direct vent gas stove

Advertisement

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before
going horizontal.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada
October 22, 2010
Part # 200-MAN

Installation Instructions

Model Number FDV200 - FDV200P
Free Standing Direct Vent Gas Stove
Stock #'s: FDV200N, FDV200LP, FDV200PN, FDV200PLP,
FDV200NE, FDV200LPE, FDV200PNE, FDV200PLPE are
Certified to: ANSI Z21.88-2009, CSA 2.33-2009
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Read this complete manual before beginning installation.
FOR YOUR SAFETY
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.

Advertisement

Table of Contents
loading

Summary of Contents for Kingsman FDV200

  • Page 1: Installation Instructions

    Installation Instructions Model Number FDV200 - FDV200P Free Standing Direct Vent Gas Stove Stock #’s: FDV200N, FDV200LP, FDV200PN, FDV200PLP, FDV200NE, FDV200LPE, FDV200PNE, FDV200PLPE are Certified to: ANSI Z21.88-2009, CSA 2.33-2009 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
  • Page 2: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 3: Table Of Contents

    Table of Contents Pre-installation Questions and Answers………………………………….. Operating Instructions………………………………………………………. Table of Contents…………………………………………………………… Mobile Home/Manufactured Housing Installation……………………..Warnings, Installations, and Operations………………………………….. Installation Requirements for the Commonwealth of Massachusetts… Installation And Operation..............Locating your Appliance................ Gas Line Installation................Gas Specifications.................. Operating And Maintenance Instructions..........10 General Glass Information..............
  • Page 4: Mobile Home/Manufactured Housing Installation

    MOBILE HOME/MANUFACTURED HOUSING INSTALLATION This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NCBS A225.1, and with CSA Z240.4 Mobile Home Standard in Canada.
  • Page 5: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the national Electrical Code;...
  • Page 6: Installation Requirements For The Commonwealth Of Massachusetts

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Installation And Operation

    INSTALLATION AND OPERATION FDV200 FDV200P ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” 15” 15” 4” Dia 4” Dia. ⁄ ” ⁄ ” 7” Dia. 7” Dia NOTE: It is recommended that a Carbon Monoxide (CO)
  • Page 8: Gas Line Installation

    GAS LINE INSTALLATION This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 installation codes for Gas Burning Appliances and Equipment in Canada and the National Fuel Gas Code Z223.1 in the United States. NOTE: IF THE OPTIONAL FAN KIT IS TO BE INSTALLED IT IS HIGHLY RECOMMENDED THAT IT BE ATTACHED TO THE STOVE BEFORE THE STOVE IS PUT IN ITS FINAL POSITION.
  • Page 9: Gas Specifications

    FDV200 - FDV200P NG/LP GAS SPECIFICATIONS FUEL MAXIMUM INPUT CONTROL (BTU) HIGH NATURAL GAS MILLIVOLT 30,000 20,000 PROPANE GAS MILLIVOLT 26,000 20,000 GAS INLET SIZE 3/8”(SIT) # 35 3/8” # 51 FULL OPEN...
  • Page 10: Operating And Maintenance Instructions

    OPERATING AND MAINTENANCE INSTRUCTIONS This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 installation codes for Gas Burning Appliances and Equipment. WARNING: WHEN PURGING THE GAS LINE, THE GLASS FRONT MUST BE REMOVED. FOR SAFE INSTALLATION AND OPERATION NOTE THE FOLLOWING: This appliance gives off high temperatures and should be located out of heavy traffic areas and away from furniture and draperies.
  • Page 11: General Glass Information

    GENERAL GLASS INFORMATION GLASS CLEANING It will be necessary to clean the glass periodically. During Warning and Cautions. start-up, condensation, which is normal, forms on the • Do not clean when the glass is hot. inside of the glass and causes dust, lint etc. to cling to the •...
  • Page 12: Installation Instructions For Logc200

    Installation Instructions for LOGC200 Remove can of touchup paint from firebox ❺ ❹ WARNING: Notch Failure to position ❷ the parts in ❸ accordance with ❻ these diagrams or ❶ Notch failure to use only parts specifically 2nd Grate Bar Notch approved with this Notch...
  • Page 13: Optional Fan Kit Installation

    OPTIONAL FAN KIT INSTALLATION Note: Leg model shown, use the same mounting procedures for pedestal models. PARTS LIST: - Mounting bracket (4000-5000 only) - 1 Variable speed control with 2 male ends - 1 black knob - 1 speed nut - 2 fan mounting screws NOTE: THE FAN ADAPTER IS NOT USED ON 200 MODEL UNITS.
  • Page 14: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING • This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 15: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 16 Conversion Kit Instructions -Part A Caution: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. PLEASE CONFIRM THAT STEP 4 IS UNDERSTOOD BEFORE PROCEEDING WITH CONVERSION. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the...
  • Page 17: Gas Conversion For Top Convertible Pilot -Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 18: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 19: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 20 the slide switch to the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to the receiver and then press the power button [R] on the transmitter. An audible beep will sound to indicate the system is programmed and ready to be used. NOTE: The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft away installed in a certified deep wall switch electrical box (2-3/4”...
  • Page 21 Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 22 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 23 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 24: Ipi Lighting Instructions

    IPI Lighting Instructions WARNING 1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed.
  • Page 25: Vent Termination

    (30cm) minimum. This appliance is approved with Kingsman flex vent system and G - Clearance from a perpendicular inside wall or outer corner to also approved for use with Simpson Duravent Direct Vent the edge of the vent terminal plate is 3”...
  • Page 26: General Venting Information

    GENERAL VENTING INFORMATION This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z-Flex)Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct Vent system, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 27: How To Use The Vent Table

    IMPORTANT: ALWAYS LOCATE THE STOVE IN SUCH A WAY AS TO MINIMIZE THE NUMBER OF OFFSETS AND/OR HORIZONTAL RUNS. A 1/4” VERTICAL RISE IS REQUIRED FOR EVERY 12” OF HORIZONTAL RUN. The following table shows the relationship between vertical and horizontal vent lengths and will help you to determine the correct vent lengths for optimum stove performance.
  • Page 28: Vent Pipe Assembly

    VENT PIPE ASSEMBLY Before joining the four inch flex pipe to stove or vent termination apply a bead of high temperature sealant (MIL PAC SEALANT IS RECOMMENDED) to the pipe and secure it with the (4) screws/washers. If two pieces of 4" flex pipe are to be joined, the joint must be siliconed and secured with four (4) screws.
  • Page 29 4. If optional fan kit has been purchased it should now be installed before stove is placed in its final position. 5. Place stove into position. Determine the lengths of the vertical and horizontal 7" pipes. Cut the 7" pipes to the correct length assuring that the following conditions have been met: The horizontal 7"...
  • Page 30: Vertical Venting Over 15 Feet

    VERTICAL VENTING OVER 15 FEET The Air Intake Plate must be adjusted down to the lowest position when venting over 15 ft. vertical. 15’ OR OVER VERTICAL VENTING AIR INTAKE PLATE ADJUSTMENT NOTE: Unit comes preset for vertical venting under 15 feet. Follow these instructions when venting exceeds 15 feet vertical.
  • Page 31: Vertical Vent Installation

    VERTICAL VENT INSTALLATION An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from chimney. When installing Attic Insulation Shield where the...
  • Page 32: Parts List

    Parts List -200ZDV Product Number Description FDV200 FREE STANDING DIRECT VENT GAS STOVES: Free Standing Direct Vent Gas Stove, Listed for USA/Canada as a Gas Fired Direct Vent Room Heater, Includes Dual Burner, Ceramic Glass, On/Off Switch Glowing Ember Rock, Hi/Lo SIT Valve, with 100% Safety Shut Off, Four & Seven inch Flue,...
  • Page 33 ZDV4FP20 Flex Pipe 4" Diameter (10' Unexpanded to 20' Expanded) ZDV4FC Flex Connector 4" Diameter ZDV4SS Spring 4" Standoff Space ZDVAAF Flashing 7" c/w Storm Collar (1/12 to 7/12) ZDVAF2 Flashing 7" c/w Storm Collar (8/12 to 12/12) ZDVAF3 Flashing 7" c/w Storm Collar Flat ZDV7SC Storm Collar 7 inch ZDVDKA...
  • Page 34: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNIING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 35: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents