This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada
October 29, 2010

Installation Instructions

Model Number FV200 - FV200P
Free Standing Vented Gas Stove
Stock #'s: FV200N, FV200LP, FV200PN, FV200PLP,
FV200NE, FV200LPE, FV200PNE, FV200PLPE are
Certified to: ANSI Z21.88-2009, CSA 2.33-2009
Listed Vented Gas Fired Free Standing Room Heater
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Read this complete manual before beginning installation.
FOR YOUR SAFETY
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Part # 200V-MAN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FV200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman FV200

  • Page 1: Installation Instructions

    Installation Instructions Model Number FV200 - FV200P Free Standing Vented Gas Stove Stock #’s: FV200N, FV200LP, FV200PN, FV200PLP, FV200NE, FV200LPE, FV200PNE, FV200PLPE are Certified to: ANSI Z21.88-2009, CSA 2.33-2009 Listed Vented Gas Fired Free Standing Room Heater INSTALLER: Leave this manual with the appliance.
  • Page 2: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 3: Table Of Contents

    Table of Contents Pre-installation Questions and Answers………………………………….. Operating Instructions………………………………………………………. Table of Contents…………………………………………………………… Warnings, Installations, and Operations………………………………….. Installation Requirements for the Commonwealth of Massachusetts… Installation And Operation..............Locating your Appliance................ Gas Line Installation................Gas Specifications.................. Operating And Maintenance Instructions..........8-9 General Glass Information..............9-10 Installation Of Brick Panel Kit..............
  • Page 4: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the national Electrical Code;...
  • Page 5: Installation Requirements For The Commonwealth Of Massachusetts

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 6: Installation And Operation

    INSTALLATION AND OPERATION FV200 FV200P Leg Model Pedestal ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” ⁄ ” 15” 15” 4” Dia 4” Dia. ⁄ ” ⁄ ” NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Gas Line Installation

    GAS LINE INSTALLATION This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 installation codes for Gas Burning Appliances and Equipment in Canada and the National Fuel Gas Code Z223.1 in the United States. NOTE: IF THE OPTIONAL FAN KIT IS TO BE INSTALLED IT IS HIGHLY RECOMMENDED THAT IT BE ATTACHED TO THE STOVE BEFORE THE STOVE IS PUT IN ITS FINAL POSITION.
  • Page 8: Gas Specifications

    FV200 - FV200P NG/LP GAS SPECIFICATIONS FUEL MAXIMUM INPUT CONTROL (BTU) FE P.4.1-02 STEADY HIGH (CDN) STATE NATURAL GAS MILLIVOLT 30,000 20,000 68.3% PROPANE GAS MILLIVOLT 32,000 25,000 68.7% GAS INLET SIZE 3/8”(SIT) # 37 1/2” # 51 FULL OPEN...
  • Page 9: General Glass Information

    The venting system (chimney) of this appliance should be inspected at least once a year and if needed, your venting system should be cleaned. Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapours and liquids.
  • Page 10: Installation Of Brick Panel Kit

    Warning and Cautions. • Do not clean when the glass is hot. • Do not use abrasive cleaners. • Using a substitute glass will void all product warranties. • Do not strike or abuse glass. Care must be taken to avoid breakage of the glass. •...
  • Page 11: Installation Instructions For Logc200

    Installation Instructions for LOGC200 Remove can of touchup paint from firebox ❺ ❹ Notch WARNING: ❷ Failure to ❸ position the parts in ❻ ❶ Notch accordance with these diagrams 2nd Grate Bar or failure to use Notch Notch only parts Locating Tabs Log and Ember Chunk Kit specifically...
  • Page 12: Optional Fan Kit Installation

    OPTIONAL FAN KIT INSTALLATION Note: Leg model shown, use the same mounting procedures for pedestal models. PARTS LIST: - Mounting bracket (4000-5000 only) - 1 Variable speed control with 2 male ends - 1 black knob - 1 speed nut - 2 fan mounting screws NOTE: THE FAN ADAPTER IS NOT USED ON 200 MODEL UNITS.
  • Page 13: Millivolt System, Lighting, And Burner Control

    MILLIVOLT SYSTEM, LIGHTING, & BURNING CONTROL WARNIING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 14 MILLIVOLT SYSTEM, LIGHTING, & BURNING CONTROL CONT. SPILL SAFETY SWITCH - Wiring Diagram 820-639 and 820-640 True Millivolt Systems This System does not have a thermocouple PILOT BURNER ADJUSTMENT Locate pilot adjustment (up and to the right approximately 1/2" from Hi/Lo control). 2.
  • Page 15: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 16 Conversion Kit Instructions -Part A Caution: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. PLEASE CONFIRM THAT STEP 4 IS UNDERSTOOD BEFORE PROCEEDING WITH CONVERSION. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the...
  • Page 17: Gas Conversion For Top Convertible Pilot -Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 18: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 19: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 20 the slide switch to the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to the receiver and then press the power button [R] on the transmitter. An audible beep will sound to indicate the system is programmed and ready to be used. NOTE: The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft away installed in a certified deep wall switch electrical box (2-3/4”...
  • Page 21 Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 22 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 23 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 24: Ipi Lighting Instructions

    IPI Lighting Instructions WARNING 1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed.
  • Page 25: Vent Installation

    VENT INSTALLATION VENTING INSTRUCTIONS NOTE: A chimney venting this stove shall not vent any other appliance. This appliance may be vented in various types of applications, 'A' Vent of solid fuel wood burning chimney. Masonry Clay lining and 'B' Vent liquid fuel gas chimney.
  • Page 26: Parts List

    Parts List -200FV Product Number Description FV200 FREE STANDING VENTED GAS STOVES: Free Standing Vented Gas Stove, Listed for USA/Canada as a Vented Room Heater, Includes Dual Burner, Ceramic Glass, Internal Rocker Switch Glowing Embers, Hi/Lo SIT Valve, with 100% Safety Shut Off, Four Inch Flue,...
  • Page 27 VALVE SYSTEM PARTS - IPI System Electronic Ignition/Remote Control IPI EGTRC Remote Control IPI (Thermostat) EGTMRCN Remote Control IPI (Thermostat/Modulating - NG) EGTMRCP Remote Control IPI (Thermostat/Modulating - LP) EGTFRCN Remote Control IPI (Thermostat/Modulating/Fan - NG) EGTFRCP Remote Control IPI (Thermostat/Modulating/Fan - LP) Electronic Ignition Replacement Parts IPI 1002-P001si Valve IPI (NG;...
  • Page 28: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not light. Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is electrode at pilot.
  • Page 29: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.