Kingsman FDV350 Installation Instructions Manual

Kingsman FDV350 Installation Instructions Manual

Free standing direct vent gas stove (field convertible to vented stove)
Hide thumbs Also See for FDV350:
Table of Contents

Advertisement

Model Numbers:
Certified to:
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Leave the building immediately.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
 If you cannot reach your gas supplier, call the fire department
-Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
Installation Instructions
Model Number FDV350
Free Standing Direct Vent Gas Stove
(Field Convertible to Vented Stove)
FDV350N, FDV350NE, FDV350NE2, FDV350LP, FDV350LPE, FDV350LPE2
ANSI Z21.88-2017 • CSA 2.33-2017
VENTED GAS FIREPLACE HEATER
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for
future reference.
For Propane Horizontal
installations the venting must
be an additional one foot
above the minimum vertical
rise off the flue before going
horizontal.
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada October 12, 2018
Part# 350-MAN17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FDV350 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman FDV350

  • Page 1 Installation Instructions Model Number FDV350 Free Standing Direct Vent Gas Stove (Field Convertible to Vented Stove) Model Numbers: FDV350N, FDV350NE, FDV350NE2, FDV350LP, FDV350LPE, FDV350LPE2 ANSI Z21.88-2017 • CSA 2.33-2017 Certified to: VENTED GAS FIREPLACE HEATER This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    FDV350 Table of Contents Table of Contents…………………………………………………………………………………………………………........FDV350 Safety Screen Attachment................................ Pre-installation Questions and Answers / Operating Instructions......................Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace................. Warnings, Installations, and Operations………………………………………………………………………………………......Installation Requirements for the Commonwealth of Massachusetts.....................
  • Page 3: Fdv350 Safety Screen Attachment

    FDV350 Safety Screen Attachment Side Panels INSTALLATION: Top Hook STEP ONE: Open Side Panels on FDV350. STEP TWO: Hook Safety Screen into Notches in FDV350 Door. STEP THREE: Spread the bottom of the Safety Screen frame slightly to engage the Bottom Retainer Tab onto the Glass Door Frame.
  • Page 4: Pre-Installation Questions And Answers / Operating Instructions

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 5: Annual Inspection List For Determining Safe Operation Of A Direct Vent Gas Fireplace

    Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace Refer to this checklist for proper maintenance, safe use, and operation. See each section for more specific information. 1. Inspect and operate all pressure relief mechanisms (i.e., relief dampers, spring loaded door latches) installed on your appliance to verify relief mechanisms are free from obstruction to operate.
  • Page 6: Warnings, Installations, And Operations

    Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 7: Installation Requirements For The Commonwealth Of Massachusetts

    Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 8: Mobile Home/Manufactured Housing Installation

    MOBILE HOME/MANUFACTURED HOUSING INSTALLATION This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NCBS A225.1, and with CSA Z240.4 Mobile Home Standard in Canada.
  • Page 9: Fireplace Dimensions / Locating Your Appliance

    FDV350 Dimensions Gas Inlet is located at the back of the unit. FDV350 Locating Your Appliance 3” 3” 3” 12” THE FOLLOWING MINIMUM DISTANCES TO 4” 2-1/2” COMBUSTIBLES MUST BE OBSERVED TO ENSURE SAFE OPERATION OF YOUR STOVE. 12” Side of Unit 1”...
  • Page 10: Optional Fan Kit Installation

    OPTIONAL FAN KIT INSTALLATION NOTE: FOR EASE OF INSTALLATION THE FAN KIT SHOULD BE INSTALLED BEFORE THE STOVE IS PUT IN ITS FINAL POSITION. AUTOMATIC ON/OFF THERMOSTAT CONTROLLED FAN KIT (Part #F45FK) 1. Open the front access door where the piezo-igniter is located. Remove the two screws that hold the control panel in place, pull the control panel out towards you and install the variable speed control in the hole provided opposite the piezo-igniter.
  • Page 11: Split Receptacle- Switch Control Outside Of Fireplace

    Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 12: F35Rl Brick Liner Installation

    INSTALLATION OF BRICK PANEL KIT PART: F35RL 1. Open side panels and remove front door and log set. (Skip this step if components are not installed at this time.) 2. The rear log holder has to be removed to install rear brick panel, using a 1/4” nut driver remove the three hex screws.
  • Page 13: Logf35 Log Installation

    F35 LOG ASSEMBLY WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Fig. 1. Remove can of touchup paint from firebox. Remove logs and bag of glowing embers chunks from carton and inspect. There are three logs and they are lettered A, B, and C.
  • Page 14: Door And Glass Information

    GENERAL GLASS INFORMATION GLASS CLEANING It will be necessary to clean the glass periodically. During Warning and Cautions. start-up, condensation, which is normal, forms on the • Do not clean when the glass is hot. inside of the glass and causes dust, lint etc. to cling to the •...
  • Page 15: Gas Line Installation

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 16: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 17: Gas Conversion For Top Convertible Pilot - Part B (Series 0190Xyz)

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 18: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C...
  • Page 19: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING  Immediately call your gas supplier from a neighbour’s phone. Follow the This appliance has a pilot which must be lighted by hand.
  • Page 20: Electronic Ignition Lighting Instructions

    Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 21: Burner Removal / Burner System Removal

    FDV350 Burner Removal / Burner System Removal -⚠ WARNING- False Bottom Turn off Unit and allow to cool before cleaning. Only a Qualified service technician should service and repair this appliance. To Remove Burner: 1. Remove False Bottom. Remove [2] DT Screws and lift out of fireplace.
  • Page 22: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not light. Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is electrode at pilot.
  • Page 23: Component Locations

    FRONT Optional Fan FRONT FDV350 Proflame 2 Box The Proflame2 IFC (Integrated Fireplace Control) board is a device that allows the automatic ignition and pilot flame supervision, to command the functions of a hearth appliance. Refer to Proflame 2 Section for more information.
  • Page 24: Proflame 2- Parts List- Basic System, Parts List, Configuration Gtmfl

    Proflame 2- Parts List- Basic System, Parts List, Configuration GTMFL ITEM PART DESCRIPTION NUMBER 1005-P001si IPI Valve NG with Stepper Motor 885.001 1005-P002si IPI Valve LP with Stepper Motor 885.001 1006-P002si IPI Valve NG Hi / Lo 1006-P003si IPI Valve LP Hi / Lo 1002-P033si Pilot NG IPI 199.059 1005-P325si...
  • Page 25: Proflame 2 Remote Control

    Proflame 2 IFC Module and Remote Control LCD Display ON / OFF Key Thermostat Key Batteries UP / DOWN Arrow Key Mode Key IFC Module Button Within 10 seconds press the button again until  Pairing Remote Control: you hear it beep. Install the 3 AAA type batteries in the battery bay, ...
  • Page 26: Cold Climates - Cpi Setting - Proflame 2 Remote Control

    Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a LCD Display flame. The CPI (Continuous Pilot Ignition) setting will keep the ON / OFF Key firebox and fireplace exhaust vent warm during cold weather.
  • Page 27: Remote Flame Control, Room Thermostat

    Proflame 2 Remote Control...
  • Page 28: Smart Thermostat, Fan Speed Control, Remote Dimmer Control

    Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
  • Page 30: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that Cover provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery Ignition/Intermittent Pilot Ignition) located on the IPI System Pack...
  • Page 31: Remote Control Operation

    -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room thermostat.
  • Page 32: Ipi Electronic Ignition Parts List - Standard System

    IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si Spark Electrode (with wire- 35” Length) 1002-P903si Electrode Flame Sensor *1002-P910si...
  • Page 33: Configuration 1: Basic Manual Hi / Lo And Manual Off

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 34: Configuration 2: Remote On / Off And Manual Hi / Lo

    Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 35: Operating The Receiver Without Batteries For Gt / Egt / Gtm / Egtm Remote Controls

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 36: Configuration 3: Remote On/Off, Variable Hi/Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 37: Vent Termination

    Vent Terminal Clearances Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. Local codes or regulations may require different clearances. WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN REQUIRED BY LOCAL CODES. Canadian installations US installations Clearance above grade, veranda,...
  • Page 38: General Venting Information

    Metal Fab Sure-Seal DV for installation of pipe and adhere to the clearance to combustibles provided in this manual. Apply a bead of Mill Pac high temp sealant to all joints of pipes, adapters and termination, when using Kingsman Flex (Z- Flex) venting and Simpson Duravent venting.
  • Page 39: Venting Routes And Components

    FDV350 Venting Routes and Components Since it is very important that the vent system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be adhered to. See venting chart for total horizontal and vertical runs For every 90°...
  • Page 40: Horizontal Venting Table

    IMPORTANT: ALWAYS LOCATE THE STOVE IN SUCH A WAY AS TO MINIMIZE THE NUMBER OF OFFSETS AND/OR HORIZONTAL RUNS. A 1/4” VERTICAL RISE IS REQUIRED FOR EVERY 12” OF HORIZONTAL RUN. The following table shows the relationship between vertical and horizontal vent lengths and will help you to determine the correct vent lengths for optimum stove performance.
  • Page 41: Horizontal Vent Installation

    FDV350 Horizontal Vent Installation Silicone and Screw Wall Thimble or Clamp Decorative Cover 1” Minimum 2-1/2” Top of Horizontal Vent 4” Top of 90° Elbow Caulk Trim Ring Silicone and Screw (Both Sides) or Clamp All other existing pipes 1” clearance.
  • Page 42: Horizontal Snorkel Terminations

    Z47ST24 / Z47ST36 Horizontal Snorkel Terminations Two snorkel terminations are available if a vertical rise is necessary on the exterior side of a building: Z47ST24 (24” Tall, 14-1/2” Center to Center) Z47ST36 (36” Tall, 26-1/2” Center to Center) Follow standard horizontal venting installation procedures. If the Snorkel Termination is to be located below grade, a window well is recommended with adequate and proper drainage as per local codes.
  • Page 43: Vertical Vent Installation

    FDV350 Vertical Vent Installation Framing Detail Attic Insulation Shield Fire Stop Using Flex Bends Use roof support and rigid pipe at roof level. Flex pipe is not permitted within roof support. When penetrating the roof a rigid galvanized pipe must be used. Attach flex pipe to the rigid pipe with high temperature sealant, secure with four screws assuring the flex pipe and rigid pipe are secured.
  • Page 44: Vertical Vent Installation

    FDV350 Vertical Vent Installation Clearance to perpendicular wall 24 inches FDVVSK: Vertical Vent Starter Kit 12” Rule (60 cm). (Recommended to prevent re- Starter Kit contains: Attic Insulation Shield, Decorative Ceiling Trim Ring, Level circulation of exhaust products. For additional Black Band, brass Band, Roof Support, Spacer Springs (6), Mill Pac.
  • Page 45: F35Bvc B-Vent Converter

    F35BVC B-Vent Converter - Installation This component will allow a direct vent fireplace to be vented like a B Vent fireplace. Parts List: - [1] B-Vent Converter FOR QUALIFIED INSTALLERS ONLY. - [3] DT Screws MUST BE INSTALLED VERTICALLY AS SHOWN. - [1] Wire Retainer FOLLOW ALL LOCAL CODES.
  • Page 46: F35Bvc B-Vent Converter

    F35BVC B-Vent Converter - Venting Information -QUALIFIED INSTALLERS ONLY- THIS B-VENT CONVERTER MUST BE INSTALLED VERTICALLY AS SHOWN. A CHIMNEY VENTING THIS STOVE SHALL NOT VENT ANY OTHER APPLIANCE. -FOLLOW ALL LOCAL CODES- A B-Vent liquid fuel gas chimney or 4” Flex pipe may be used. This appliance may be vented in various types of applications, including: When installing with B-Vent liquid fuel gas chimney, install as per B-Vent...
  • Page 47: Parts List

    FDV350 Parts List F7DTP Decorative Black Wall Trim Plate -FDV350 KINGSMAN STOVE- FREE STANDING DIRECT VENT GAS STOVE VALVE SYSTEM PARTS / MILLIVOLT Listed for USA/Canada as a Vented Gas Fireplace Heater, Dual Burner, Ceramic Glass, Glowing Embers, 4/7” Flue...
  • Page 48 CONVERSION KIT KINGSMAN FIREPLACE VENTING 350DV-CKLP Conversion Kit - Millivolt - To Propane Horizontal Vent Starter Kit - (Direct Vent FDVHSK 350DV-CKNG Conversion Kit - Millivolt - To Natural Stoves) Starter Kit Contains: Horizontal Vent Termination, Zero Clearance 350DV-CKLPI Conversion Kit - Proflame 1 - To Wall Sleeve, Black Wall Trim Ring, 7"...
  • Page 49: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.